Fluke now extends the 190 Series of portable oscilloscopes with the new two-channel 190-062 model built for industrial plant maintenance professionals who work on:
- Heavy-duty electrical equipment
- Electro-mechanical machinery
- Plant automation control systems
The Fluke 190062 2 Channel ScopeMeter oscilloscopes from Fluke, with electrically isolated channels, are safety rated for industrial applications. These scopes combine rugged portability with the high performance of bench oscilloscopes to take you from troubleshooting microelectronics all the way into power electronic applications.
The Fluke 190 Series II Models, 190-062, with a wide range of bandwidth options. Fast sampling rates up to 625 MS/s, 400 ps resolution and deep memory of 10,000 samples per channel allow high-accuracy capture and display of waveform details, noise, and other disturbances.
Perform timing or amplitude related measurements on three phases or three-axis control systems or simply compare and contrast multiple test points in a circuit under test. Features like TrendPlot, ScopeRecord, and Connect-and-View help you quickly diagnose industrial machinery, automation and process controls, and power electronics to minimize repair costs and downtime. These features make the oscilloscopes easy to use especially when diagnosing the most difficult problems like complex waveforms, intermittent events and signal fluctuations or drift.
|
|
Introducing the first two-channel scope with CAT IV rating The first CAT III 1000 V/CAT IV 600 V rated, four-channel portable scope on the market, the new Fluke 190 Series-II brings an unprecedented combination of performance and ruggedness into the field.
Take on new challenges in industrial machinery, automation and process controls, power conversion electronics Analyze timing and amplitude relationships of multiple signals simultaneously, easily compare and contrast waveform traces spotting irregularities with ease.
- For three-phase power applications like industrial motors and drives, UPS and inverters for wind energy, and diesel locomotive controls for transportation
- For three-axis testing when you need to measure input, output and control signals simultaneously
The ultimate in portability New high-performance batteries take advantage of Li-ion technology to keep you going strong for a full shift. With the easy-access battery door of the Fluke 190/062 you can make battery swaps fast.
New USB connectivity makes it easy to capture and share waveforms The new Fluke 190 Series II offers two USB ports, electrically isolated from measurement input circuits. Easily transfer data to a PC. Archive and share waveforms with OEMs, colleagues and support staff. Store unlimited waveforms, screen captures and instrument setups onto USB memory devices.
|
Easily diagnose timing-related issues with multiple signals
- Real-time inspection of multiple related signals simultaneously
- Measure a combination of input and output signals and system safety interlocks and feedback loops
Take multiple measurements simultaneously and track down the root cause of your most complex troubleshooting challenges. |
|
For industrial electronics, four channels allows you to perform three-dimensional testing, measuring input, output and feedback signals simultaneously. |
|
In three-phase systems like variable speed drives, UPS or back-up generators, use four channels to diagnose power input, dc to ac converters, or cable interface problems. |
Find problems in industrial systems including:
- Circuit voltage/current overloading
- Attenuation/input impedance mismatch
- Signal fluctuation/drift
- Conditioning circuits signal integrity
- Test point verification for critical signals
- Input/output/feedback timing issues
- Induced noise and disturbances
- Random shutdowns/reset
Diagnose VSDs or power inverters and converters
- Harmonics, transients and loads in three-phase power input
- Troubleshoot dc to ac converters for faulty control circuits or output IGBT gate stages
- Cable interface—test PWM output for reflections and transients
|
|
Fluke ScopeMeter test tools work harder to make your job easier See what’s happening with fast real-time high resolution sampling. ScopeMeter offers a sample rate of up to 625 MS/s with up to 400 ps resolution
Connect-and-View triggering for an instant, stable display If you’ve used other scopes, you know how tricky triggering can be. If settings are incorrect, results can be unstable or incorrect. Connect-and-View automatically sets up correct triggering by recognizing signal patterns. Without touching a button, you get a stable, reliable and repeatable display of virtually any signal including motor drive and control signals. It’s especially fast and convenient when you’re measuring a number of test points in rapid succession.
ScopeRecord mode for high resolution waveform recording up to 48 hours Included on both the Fluke 190062 Scope Record memory stores up to 27,000 data points per channel, capturing fast intermittent and glitches as short as 8 ns. (Two sets of multiple-channel recordings can be stored for later analysis.)
- Stores events like motion profiles, UPS, power supply and motor start-ups
- With the Stop on Trigger mode, the ScopeMeter automatically recognizes a power failure and stores the wave-form data preceding it
- With the waveform zoom (up to 100x) you can look at the smallest details, like individual power cycles
|
TrendPlot paperless recorder—records up to 16 days to help you find intermittent faults The toughest faults to find are those that happen once in a while. These intermittents can be caused by bad connections, dust, dirt, corrosion, or simply broken wiring or connectors. Line outages, sags or starting and stopping of a motor can also cause a machine to stop. You may not be around when it happens, but the Fluke 190 Series II ScopeMeter will.
- Plot minimum and maximum peak values and average over time up to 16 days
- Plot any combination of volt-ages, amps, temperature, frequency and phase for all four inputs, all with time and date stamp to pinpoint faults
|
Look back in time with automatic capture and display of last 100 screens It’s frustrating to see a one-time anomaly flash and miss it. Fluke 190062 ScopeMeter will solve the problem by letting you look back in time with a touch of the replay button.
- In normal use, the instrument continuously memorizes the last 100 screens. As each new screen is acquired, the oldest is discarded.
- At any moment you can "freeze" the last 100 screens and scroll through picture-by-picture or replay as a "live" animation
- Use cursors for further analysis
- With advanced triggering you can capture up to 100 specific events (Two sets of 100 captured screens with individual time stamps can be stored for later recall or downloaded to a PC.)
|
Cursors and automatic waveform measurements With 30 automatic measurements, cursors, zoom and a real-time clock, the Fluke 190-062 ScopeMeter will perform automatic power and Vrms measurements on the specific portion of the waveform you select within a specified time span.
|
|
Specifications |
Vertical deflection |
Bandwidth |
60 MHz |
Real-time sample rate |
625 MS/s |
Channels |
2 |
Number of scope inputs |
2 input channels plus external trigger |
Rise Time |
5.8 |
Accuracy |
± (2.1 % of reading + 0.04 x range/div) @ 5 mV/div to 100 V/div |
Channel architecture |
All inputs fully insulated from each other and from ground Inputs may be activated in any combination |
Input coupling |
AC or DC, with ground level indicator |
Input sensitivity |
2 mV/div to 100 V/div, plus variable attenuation |
Bandwidth limiter |
User selectable: 20 kHz, 20 MHz or full bandwidth |
Normal/invert/variable |
On each input channel, switched separately |
Input voltage |
CAT III 1000 V/CAT IV 600 V rated |
Input impedance |
1 MΩ ± 1 % // 14 pF ± 2 pF |
Vertical resolution |
8 bit |
Horizontal deflection |
Max. real-time sample rate (sampled simultaneously) |
625 MS/s for each channel |
Record length |
Up to 10,000 samples per channel |
Time base range |
10 ns/div to 4 s/div |
Time base in a 1-2-4-sequence Slower time/division settings using ScopeRecord Roll mode |
Glitch capture |
8 ns |
Scope measurements |
Cursor |
7 |
Automatic |
30 |
Maximum Record length |
ScopeRecord mode |
30,000 pts per input |
Scope mode |
10,000 pts per input |
Timing accuracy |
± (0.01 % of reading + 1 pixel) |
Meter Modes |
Meter inputs |
Via 4 mm banana inputs, fully isolated from scope inputs and scope ground |
Number of readings |
One at a time |
Maximum resolution |
5,000 counts |
Input impedance |
1 MΩ ± 1 % // 14 pF ± 2 pF |
Advanced meter functions |
Auto/manual ranging, relative measurements (Zero reference), TrendPlot recording |
Horizontal deflection |
Vdc accuracy |
± (0.5 % + 5 counts) |
Vac true rms accuracy |
15 Hz to 60 Hz |
± (1 % + 10 counts) |
60 Hz to 1 kHz |
± (2.5 % + 15 counts) |
Vac+dc true rms accuracy |
15 Hz to 60 Hz |
± (1 % + 10 counts) |
60 Hz to 1 kHz |
± (2.5 % + 15 counts) |
Voltmeter ranges |
500 mV, 5 V, 50 V, 500 V, 1,000 V |
Resistance |
Ranges |
500 Ω, 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ |
Accuracy |
± (0.6 % + 5 counts) |
Other meter functions |
Continuity |
Beeper on < 50 Ω (± 30 Ω) |
Diode test |
Up to 2.8 V |
Current (A) |
Adc, Aac, Aac+dc using an optional current clamp or shunt Scaling factors: 0.1 mV/A, 1 mV/A to 100 V/A and 400 mV/A |
Temperature |
With optional accessories. Scale factors 1 °C/mV or 1 °F/mV |
|