Kyoritsu 2009R

CAT.IV Clamp Meter can measure the Voltage and Current in both very low and high power circuits.
Accurate True-RMS reading of AC current or voltage with distorted waveform.
Can measure AC and DC currents up to 2000A.
AC A
400.0/2000A
±1.3%rdg±3dgt (0~400.0A, 150~1700A) (45~66Hz)
  ±2.0%rdg±5dgt (0~400.0A, 150~1700A) (20Hz~1kHz)
  ±2.3%rdg±3dgt (1701~2000A) (45~66Hz)
DC A 400.0/2000A±1.3%rdg±2dgt
AC V
40.00/400.0/750V
±1.0%rdg±3dgt (45~66Hz)
  ±1.5%rdg±5dgt (20Hz~1kHz)
DC V 40.00/400.0/1000V±1.0%rdg±2dgt
Ω 400.0/4000Ω|±1.5%rdg±2dgt
(Electronic protection (no fuse) up to 600V)
Continuity buzzer Buzzer sounds below 20Ω
Hz 10.0 ~ 4000Hz±1.5%rdg±5dgt
(Input sensitivityCurrent: more than 40AVoltage: more than 10V)
Output
Recorder : DC400mV against AC/DC400.0A
  DC200mV against AC/DC2000A
Withstand voltage 6880V AC for 5 seconds
Conductor size Ø55mm max.
Applicable standards IEC 61010-1 CAT.IV 600V, CAT.III 1000V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326-1, IEC 61326-2-1
Power Source R6P (1.5V) × 2
Dimensions 250(L) × 105(W) × 49(D)mm
Weight Approx. 540g (including batteries)
Accessories 7107A (Test leads), 8201 (Output plug), 9094 (Carrying case)
R6P (AA) (1.5V) × 2, Instruction Manual
Optional 8008 (Multi-Tran) (AC only), 7256 (Output cord)

Location

Ask about this product