Kyoritsu

  • Filter

This panel demonstrates the use of Kyoritsu Leakage Clamp Meters in troubleshooting nuisance tripping of RCD's due to leakage currents. It includes an RCD with bypass facilities and 5 downstream circuits. Each circuit can simulate a fixed/variable leakage current by selecting an appropriate switch. Using a Kyoritsu Leakage Clamp the overall leakage current can be found and the source of leakage current direction can be traced by clamping the conductors in each circuit. There can also be a combination of one or more leakage currents, for instance, it is possible to simulate a situation of an RCD tripping due to two faulty circuits, one with a fixed leakage current and the other one with variable leakage current (for example due to humidity).

This demonstrative panel is intended to demonstrate the use Multifunction testers and specific instruments like Continuity, Insulation, Earth, Loop and RCD testers of Kyoritsu. The panel simulates an electrical installation with TT and TN distribution systems, easy selectable by a switch on the panel. The tests that can be carried out are: • Continuity Test of Protective and Equipotential conductors • Insulation Resistance Test • Earth Resistance Test (Volt-Ampere method) • Earth Loop Test, including Prospective Short circuit Current (PSC) and Prospective Fault Current (PFC) • RCD Tripping Test

Category: Clip etc.

Applicablemodel   4106   • Cord reel • 4reels/set

Category: Clip etc.

Applicablemodel   7100A   • Cord reel • 3reels/set

Applicable model 5010/5020, 6310, 6315 * Cannot be used for power measurement.

Applicable model 5010/5020, 6310, 6315 * Cannot be used for power measurement.

Applicable model 5010/5020, 6310, 6315 * Cannot be used for power measurement. Conductor size Φ24 Rated current AC 30A Output voltage AC 1500mV/30A (AC 50mV/A) Accuracy 0~15A|±1.0%rdg±0.1mV (50/60Hz)|±2.0%rdg±0.2mV (40Hz~1kHz) 15~30A|±5.0%rdg (50/60Hz)|±10.0%rdg (45Hz~1kHz) Withstand voltage AC 3540V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~50ºC, less than 85% RH (without condensation) Output impedance Approx. 90Ω Applicable standards IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 300V pollution degree 2 Dimensions 100(L) x 60(W) x 26(D) mm Weight Approx.150g Accessories 9095 (Portable case), Instruction manual, Cable marker Option 7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)

Applicable model 5000/5001, 5010/5020, 6310 * Cannot be used for power measurement.