Kyoritsu

  • Filter
Category: Power Meter

Load current clamp sensor Applicable model 5010/5020, 6300, 6305, 6310, 6315

Applicable model 5010/5020 Conductor size Φ55 Rated current AC 1000A Output voltage AC 500mV/1000A (AC 0.5mV/A) Accuracy |±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz) Withstand voltage AC 5350V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~40ºC, less than 85% RH (without condensation) Output impedance Approx. 1.5Ω Applicable standards IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 600V pollution degree 2 Dimensions 170(L) x 105(W) x 48(D) mm Weight Approx.360g Accessories 9094 (Portable case), Instruction manual, Cable marker Option 7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)

Applicable model 5010/5020 Conductor size Φ40 Rated current AC 500A Output voltage AC 500mV/500A (AC 1mV/A) Accuracy |±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz) Withstand voltage AC 5350V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~40ºC, less than 85% RH (without condensation) Output impedance Approx. 1.9Ω Applicable standards IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 600V pollution degree 2 Dimensions 128(L) x 81(W) x 36(D) mm Weight Approx.260g Accessories 9095 (Portable case), Instruction manual, Cable marker Option 7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)

Applicable model 5010/5020 Conductor size Φ24 Rated current AC 100A Output voltage AC 500mV/100A (AC 5mV/A) Accuracy |±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz) Withstand voltage AC 3540V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~40ºC, less than 85% RH (without condensation) Output impedance Approx. 9.5Ω Applicable standards IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 300V pollution degree 2 Dimensions 97(L) x 59(W) x 26(D) mm Weight Approx.150g Accessories 9095 (Portable case), Instruction manual, Cable marker Option 7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)

Permits extension of the AC and DC current ranges of almost any Digital Multimeters (DMMs) without breaking the circuit under test. • Using KEW 8115 with KEW 1051/1052 (DMM) the display can be set for direct reading in A.

AC/DC CLAMP ADAPTOR • Model 8113 is a clamp-on AC/DC current/voltage converter that permits AC/DC current measurements from 1mA to 200A in conjunction with a voltmeter having 0.1mV resolution.

AC CLAMP ADAPTOR Model 8112BNC is an AC clamp adaptor designed for use with oscilloscopes. Output cord has a BNC connector which enables direct observation of current waveform on oscilloscope. Refer to a diagram shown at left for application. Specifications are same as those for Model 8112.

AC CLAMP ADAPTOR • Model 8112 clamp adaptor is designed to be an AC current/voltage conversion probe capable of measuring AC current from 0.1mA to 120A in conjunction with digital multimeters. Simple to operate, the unit has range switch position at 200mA,2A and 20A. It also features safety design throughout with no exposed metal parts.