Kyoritsu

  • Filter

Continuity Measurement Continuous testing can be carried out by use of the test button lockdown feature. A selectable buzzer gives instantaneous indication of continuity. Null facility eliminates the test lead resistance from the results, the nulled value is retained even if the instrument is switched off. Live circuit warnings are given by a flashing LED, buzzer and indication on the display. Insulation Measurement Three selectable test voltages 250V, 500V and 1000V. An auto-discharge function ensures that circuits are not hazardous after testing. A red LED gives warning of high voltage output during testing and discharging of the circuit. In case of connecting to a live circuit, a live circuit warning is given by flashing LED, buzzer and indication on the display. Loop Impedance Measurement A patented (ATT) low current loop impedance test enables high accuracy loop measurements and quick testing without tripping RCD's. A high current alternative is selectable for even higher accuracy and instantaneous results. The subsequent test will default to the low current test, this saves any inadvertent tripping of the RCD. The KEW...

Category: Combi Tester

Kew Combitester provides the ultimate in Microprocessor technology offering Loop and RCD tests with a comprehensive memory and downloading test results. • LOOP Impedance 200/2000Ω range measurement is carried out using a test current of 15mA. This current will not trip RCD’s rated at 30mA or greater. • High resolution for low Loop Impedance (resolution of 0.01Ω) on 20Ω range. • Direct reading of Prospective Short Circuit Current (PSC) and earth fault current. • RCD tests at 0 and 180 degree phase angle switch permit quick tests and consistent readings. • Test of a large kind of RCD's:Standard, Selective, AC and A (DC sensitive breakers). • Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings. • RCD Ramp test in order to indicate the actual tripping current of RCD. • Contact Voltage Reading (UC). with two selectable contact voltage limits (50 and 25V). • Visual indication of correct wiring status and automatic lock-out if test resistors overheats. • Designed to IEC 61010-1, IEC 61557 and high protection degree IP54. • The...

The KEW 6201A is a portable appliance tester, performing four functions to ensure the Safety of ClassI and ClassII appliances. And also can measure the mains voltage. Readings are displayed on a large liquid crystal display (LCD) below which are four LEDs which unambiguously display a pass or fail indication for threshold values dictated by AS/NZS 3760.

Category: Power Meter

Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems • Voltage, Current, Power Factor and Frequency measurements • Power analysis (Active, Apparent and Reactive power) • Energy analysis (Active, Apparent and Reactive power) • Active power accuracy: ±0.3%rdg±0.2%f.s. • Automatic wiring check function to prevent incorrect connections • Large memory capability (2GB) using built-in SD card interface • Real time & remote measurements using Android application • synchronous measurements between two units of KEW 6305 • Wide selection of clamp sensors allow measurements from 0.1A to 3000A • The instrument automatically recognizes what kind of clamp sensor is connected to it

Permits extension of the AC and DC current ranges of almost any Digital Multimeters (DMMs) without breaking the circuit under test. • Using KEW 8115 with KEW 1051/1052 (DMM) the display can be set for direct reading in A.

MODEL Descriptions Remark Alternative 1007 Digital Multimeter   1009 1008 Digital Multimeter   1009 1010 Solar Pocket Tester Solar battery No 1015 Digital Multimeter   1018 1017 Digital Multimeter   1018 1020 Digital Multimeter Automatic mode switchingbetween AC and DC voltage measurements. No 1103 Analogue Multimeter   1110 1104 Analogue Multimeter with 1000V range and10A range 1109S 1106 Analogue Multimeter   1110 1108 Analogue Multimeter   1109S 1109 Analogue Multimeter   1109S 1601 Analogue Multimeter   No 1700 Voltage Tester   KT 170 1710 Voltage Tester   KT 171 2002 Digital Clamp Meter   2002PA,2002R 2009A AC/DC Digital Clamp Meter   2009R 2037 AC/DC Digital Clamp Meter   2046R 2103 Analogue Clamp Meter   No 2401 Analogue Leakage Clamp Meter Equivalent battery type: P625U No 2411 Analogue Leakage Clamp Meter Equivalent battery type: P625U No 2417 Leakage Clamp Meter   No 2904 Analogue Clamp...

Capable of measuring AC and DC currents up to 60A with OPEN CLAMP SENSOR. • 3400 counts with bargraph display. • Pocket size and heavy duty design.  

Category: Logger

THE LEAKAGE CURRENT IS RECORDED BY 3CH INPUT60,000 DATA IS RECORDED 60,000 data is recorded when 1ch is used and when three all channels are used, 20,000 data is recorded for each channel Continuous measurement time   About 40 days   Data where it doesn’t disappear even if battery is consumed   Data doesn’t disappear by using the nonvolatile memory when the battery is consumed and the battery is exchanged. (warranty for 10 years)   Battery residual display   The battery state is displayed by 4 stages. (When blinking is displayed, it is possible to measure for about one day)   The present time, recording intervals, the start of recording, the recording method, the name of monitoring site and the comment can be set by using supplied software