Water

Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen and two hydrogen atoms connected by covalent bonds. Water is a liquid at standard ambient temperature and pressure, but it often co-exists on Earth with its solid state, ice, and gaseous state (water vapor or steam). Water also exists in a liquid crystal state near hydrophilic surfaces.

 
  • Filter
Category: Water

Accessories: Sulphide Ion Selective Electrode (Made in US) TP-10K Temperature Probe Storage Bottles Carrying Case and "AA" Batteries

Category: Water

Features: Compact 1/16 DIN size fits into standard industry panel cutouts. Microprocessor based for fast, reliable and accurate measurements. Easy to calibrate by one keyboard. Degree ℃/℉ are switchable. The large backlight LCD display pH or Conductivity and Temperature simultaneously. Optional NEMA-4X gasketed lens cover fits over front bezel of controller-made of watertight corrosion resistant ABS plastic. Specifications:     pH ORP Temp Conductivity TDS Salt Temp Range -2~16.00 ±1000 mV 0~90.0 ℃ 0~2000μS 2.00~20.00 mS 0-1300 ppm 1.30~13.00 ppt 0~1000 ppm 1.00~10.00 ppt 0~90 ℃ Accuracy ±0.01+1 digit ±2+1 digit ±0.2+1 digit ±2% FS ±0.2+1 digit Resolution 0.01 pH 1 mV 0.1 ℃ 1 μS/0.01 mS 1 ppm/0.01 ppt 1 ppm/0.01 ppt   Power 9V DC  (AC adaptor) Panel cutout 1/16 DIN/1.77 x 1.77"(45 x 45 mm), Depth 4.2"(106 mm) Weight 70 g without NEMA-4X   Accessories for complete kit: pH, ORP electrode or Conductivity cell Temperature probe Standard solution DC/AC adaptor

Category: Water

Features: Compact 1/16 DIN size fits into standard industry panel cutouts. Microprocessor based for fast, reliable and accurate measurements. Easy to calibrate by one keyboard. Degree ℃/℉ are switchable. The large backlight LCD display pH or Conductivity and Temperature simultaneously. Optional NEMA-4X gasketed lens cover fits over front bezel of controller-made of watertight corrosion resistant ABS plastic. Specifications:     pH ORP Temp Conductivity TDS Salt Temp Range -2~16.00 ±1000 mV 0~90.0 ℃ 0~2000μS 2.00~20.00 mS 0-1300 ppm 1.30~13.00 ppt 0~1000 ppm 1.00~10.00 ppt 0~90 ℃ Accuracy ±0.01+1 digit ±2+1 digit ±0.2+1 digit ±2% FS ±0.2+1 digit Resolution 0.01 pH 1 mV 0.1 ℃ 1 μS/0.01 mS 1 ppm/0.01 ppt 1 ppm/0.01 ppt   Power 9V DC  (AC adaptor) Panel cutout 1/16 DIN/1.77 x 1.77"(45 x 45 mm), Depth 4.2"(106 mm) Weight 70 g without NEMA-4X   Accessories for complete kit: pH, ORP electrode or Conductivity cell Temperature probe Standard solution DC/AC adaptor

Category: Water

  90 degree scattered light method   Turbidity Checker TSC-10(E) uses a method of 90 degree scattered light as the measuring principle of the world common standard. Built-in wiper cleaning system   The built-in wiper cleaning system certainly keeps lenses clean. Sapphire glass of the optical windows   The optical windows are made of hard-to-scratch sapphire glass. It enables to scrub the window surface to maintain the Turbidity Checker. Compact design   The compact design makes it possible to install easily. Turbidity Checker TSC-10(E) got the Pattern Approval Certificate of the measuring instruments of the People's Republic of China. Model No. TSC-10(E) Measuring range 0.00-500.0 (NTU/FNU) Power supply voltage AC100-240V±10% 50/60Hz Power consumption Nomal:15VA or less, During cleaning:22VA max. Display resoltion 0.01(0.00-19.99), 0.1(20.0-500.0)NTU/FNU Output Signal Output (analog 4-20mA, resistance load of 300 max.) Self-checking Relay Output (non-voltage C-contact capacity 240VAC,...

Category: Water

    This checker can be used for continuous monitoring of the water turbidity (TC-100/500/3000) and suspended solids (TCS-1000) .   Analogue output (4-20mA) allows you to use this checker with various equipments. Wiper for easy maintenance   Original wiper certainly keeps lenses clean. Stain of lenses need to be checked only once a month. Compact size   Simple cylindrical design in compact size approx ¢32 x 170mm (1.26 x 6.69 inch). Requires small space to set up the unit. High durability   Durable stainless steel has been used for the sensor casing. Stainless steel = 18-15-2.5 Cr-Ni-Mo low C stainless steel Lenses are made of hard-to-scratch sapphire glass. Turbidity Checker TC-100/500/3000 SS Checker TCS-1000 The transmitter is also available to use in combination with the Turbidity Checker / SS Checker.   As well as the turbidity/SS indication, this transmitter can indicate signal output response...

Category: Water

    Easy to measure turbidity.   You can easily measure the water turbidity anywhere with this portable sensor because it cannot be affected by external disturbance light. Unnecessary to draw the water.   You just put the probe into the water to measure turbidity. You can avoid the hassle of drawing the water. High durability   Controller Unit: Waterproof IP67. Anti-bacterial metrical is used. Sensor Unit: Durable SUS316L is used. Optical window is made of sapphire glass. It is equipped with a rubber to absorb the impact from wear and shock.   Model No. TD-M500 Measuring Technique Attenuated Light Method Measuring Range 0.0-500FTU Display Resolution 0.1FTU (0.0-99.9), 1FTU (100-500) Calibration Distilled Water or Air Calibration Correction Single or Double Point Correction Power Requirements 9V Layer-built Alkaline Dry Battery (6LR61) Battery Life Approx. 8000 measurements Water Temperature 0 to 40℃ (32 to 104°F) Operating...

Category: Water

  The transmitter is also available to use in combination with the Turbidity Checker / SS Checker.   As well as the turbidity/SS indication, this transmitter can indicate signal output response time, alarm level setting and so on. You can control the turbidity/SS utilizing its functions fully. Power Supply 50/60Hz Signal output Alarm output Degree of protection Jet-proof type (IP65) Transmitter forSuspended Solids Checker

Category: Water

    This checker can be used for continuous monitoring of the water turbidity (TC-100/500/3000) and suspended solids (TCS-1000) .   Analogue output (4-20mA) allows you to use this checker with various equipments. Wiper for easy maintenance   Original wiper certainly keeps lenses clean. Stain of lenses need to be checked only once a month. Compact size   Simple cylindrical design in compact size approx ¢32 x 170mm (1.26 x 6.69 inch). Requires small space to set up the unit. High durability   Durable stainless steel has been used for the sensor casing. Stainless steel = 18-15-2.5 Cr-Ni-Mo low C stainless steel Lenses are made of hard-to-scratch sapphire glass. Turbidity Checker TC-100/500/3000 SS Checker TCS-1000 The transmitter is also available to use in combination with the Turbidity Checker / SS Checker.   As well as the turbidity/SS indication, this transmitter can indicate signal output response...