FEATURES ● The TEL1 is the Basic Test Equipment an Electrician cannot do   without. TEL1 is a Dual Function Test Instrument utilized to Verify   Electrical Wiring Connections and the Functioning of Earth Leakage   / Residual Current Detectors devices by forcing the ELCB/RCD to   trip.     SPECIFICATIONS         Nominal Voltage System 110V-220V-230V-240Vac available - User Selectable at purchase. System Voltage Frequency 50-60Hz Wiring Check Accuracy Table Valid for Voltage within 5% of nominal voltage. If voltage differs from Nominal Voltage System by more than 5%, table may be incorrect. Earth / Ground Current Simulator Accuracy Current is set by Selected Resistors and therefore Proportional to Voltage. Resistance Accuracy is 10% Maximum. Overall Rating Intermittent Rated (Press TEST Shortly). DO NOT KEEP PRESSING TEST. Resistance Rating Current Injection System uses Resistors which are Not Continuously Rated. Case Material ABS Safety Standard EN 61010-1 EN...

FEATURES ● Mains wiring polarity check.● ELCB/RCD testing.● Measuring ear for line current.● Measuring ear for leakage current.● Helps calculate insulation resistance.● Helps calculate power consumption.● Helps fault finding of standing earth fault.● Fused main adapter.● Appliance testing (with the aid of a clamp meter).● Fused appliance socket.● No batteries required.● HRC fuse inside.● Fused, color-coded universal test sockets.● Universal mains IEC Lead.     SPECIFICATIONS       Voltage / power input     Universal IEC LEAD 240V/10A Wiring polarity check     Nominal Voltage 240Vac Frequency 50/60Hz Mains Voltage Tolerance ±10% Elcb / rcd tester     Nominal Voltage 240Vac Frequency 50/60Hz Current Tolerance (current proportional to Line to Earth Voltage) ±10% Universal test sockets     Nominal Voltage 240Vac Frequency 50/60Hz Mains Voltage Tolerance ±10% Fuse 10A Appliance tester     Nominal...

FEATURES ● Wiring check.● Can be used on 2 wires L-E (ELCB/RCCB/GFCI tester).● Can be used on 3 wires L-E-N (with wiring check).● Sense automatically 50 or 60 Hz.● No battery required.● Simple operation.● Current injected in phase with the voltage.● Fused.● Wide operating voltage (195Vac to 265Vac).● Other voltage optional (110V).● Robust.     SPECIFICATIONS         Wiring check LEDs Line-Neutral = Green Line-Earth = Green Neutral-Earth =Red Current settings 10-50mA@230Vac> Current selection Knob Frequency of operation 50/60 Hz Sinusoidal Over-Temperature Protection Yes by NTC sensor Test stopped indication by Red Led. Operating voltage (L-E) 230 Vac ±15% Meter accuracy ±3% of full scale Operating temperature -5°C to 45°C Storage temperature -10°C to 55°C Dimensions 150(L) × 73(W) × 50(D)mm Weight Approx. 220g Safety standard EN 61010-1 CAT III 265V EN 61326-1

FEATURES ● High contrast OLED display.● Designed for viewing in the dark, for mining industry.● Microprocessor-controlled.● Indicates phase rotation● Indicates phase presence● TEST for disconnection sensitivity● Battery status indicator● Measures Voltage Phase to Earth● Select one of 3 Phase to test ELCB.● Color-coded test leads.● Phase presence indication from as low as 100Vac.● Fused earth leakage tester.● ELCB works 50Vac to 330Vac 50Hz / 60Hz.● Phase rotation and presence does not require battery to indicate.     SPECIFICATIONS       Nominal voltage for phase presence frequency range 100Vac to 450Vac 10Hz to 400Hz Rotary field direction phases frequency range 100 to 450Vac 2Hz to 400Hz Overload protection 550V (between all terminal) Over voltage protection Class III - 450V towards ground Current settings 999mAac /50Hz-60Hz Phase start selection 0º and 180º Phase polarity trip Indicator ˇ Operating voltage (L-E) referenced to earth 220Vac to 317Vac Timer resolution 1ms (Max....

FEATURES ● Microprocessor-controlled.● Indicates phase rotation.● Indicates phase presence.● Tests for disconnection sensitivity.● Indicates battery status.● Tests for disconnection time.● Measures voltage phase to earth.● Select one of 3 Phase to test ELCB.● Color-coded test leads.● Phase presence indication from as low as 100Vac.● Very low consumption.● Fused earth leakage tester.● ELCB works 50Vac to 330Vac 50Hz / 60Hz.● Led indication of Voltage on ELCB.● Phase rotation and presence does not require battery to indicate.● EN 61010-1 CAT III 550V. EN 61326-1     SPECIFICATIONS     Determination of the Phase Presence     Nominal Voltage for Phase Presence Indication (the voltage required for the neon lamps L1, L2, L3 to lit up) From 100Vac to 450Vac. Frequency Range From 10Hz to 400Hz. Determination of the Phases Rotary Field Direction   Direction (the voltage required to have the direction LEDs L1-L2-L3 or L2-L1-L3 to indicates) From 100 to 450Vac. Frequency Range From 2Hz to...

FEATURES ● Microprocessor technology ensures high    performance accuracy and reliability.● Fully programmable via tactile key pad.● Direct readout of disconnection, time or current. ● Voltage measured during test.● Housed in a heavy duty carry case.● Suitable for all industrial, mining and domestic     environments.● Display can be customized for special orders.● Indicate voltage and trip Current/Time.● Use binary principle.● True resistor switching.     SPECIFICATIONS       Rated tripping current at 317V 1000mA (2000mA on special orders) Lowest resolution 1mA System voltage 230 / 380 / 550V (50Hz) Maximum trip time 99.99s Highest resolution 10ms Typical Accuracy Rated trip current ±1%rdg ± 2dgt Voltage range ±1%rdg ± 1dgt Trip-time ±1%rdg ± 2dgt Voltage 0°C to 40°C Operating-humidity 80% Max. relative humidity Dimensions 330(L) × 260(W) × 160(D)mm Weight (battery included) Approx. 3700g Power source 1.5V “C” × 8...

FEATURES ● Microprocessor-controlled.● 2 Lines × 16 Characters LCD.● Very low consumption.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity Shown on LCD.● Auto off and off override.● Polarity Trip indicator (Positive or Negative Phase).● Wiring polarity indicator.● Measure voltage between line and earth before testing.● Indicates frequency of voltage L-E.     SPECIFICATIONS         Current settings 3mA, 5mA, 7mA, 10mA, 15mA, 20mA, 30mA, 35mA, 50mA, 100mA, 125mA, 150mA, 175mA, 250mA, 300mA, 375mA, 500mA. Current selection Rotary switch Phase start selection 0° and 180° Referenced to Earth Yes Over-temperature protection Yes Wiring correctness indication Yes Trip indicator Yes Phase polarity trip Indicator Yes Operating voltage (L-E) Referenced to Earth 240Vac-50Hz or 60Hz Voltage Model (Vac) Timer resolution 1ms (Max. Time=19.99s) Timer accuracy 1ms...

FEATURES ● Microprocessor-controlled.● Operating voltage 100-450V L-E.● Rated current 999mA, at 317V AC/50Hz.● Checks ELCB trip time and trip point (sensitivity).● Auto off and auto ranging.● Phase angle selection(0° / 180°).● Indicates tripping phase angle.● Impact resistant enclosure.● Over temperature shut-down.● Transient protection.● Suitable for heavy industrial use.● Fused.     SPECIFICATIONS         Trip current-range 0-1A at 317V (Auto-Rang Programmable) Trip current- resolution 1mA Operating voltage (L-E) 100 - 450V Phase angle setting 0° and 180° selectable Timer-max 99.999s Timer resolution 1ms Typical Accuracy Trip-current ±1%rdg±1mA Trip-time ±1%rdg±1dgt Voltage ±3%rdg±1dgt Operating temperature - humidity -10°C to +40°C 80% Max. relative humidity Dimensions 170(L) × 120(W) × 95(D)mm Weight (battery included) Approx. 800g Power source 1.5 (AA) × 8 Safety standard EN 61010-1 CAT III 450V EN...