SEW-Taiwan

Phase sequence indicators

  • Filter

FEATURES ● Three functions in one unit: open phase, phase     sequence and motor rotation indication.    ● Large size alligator clips for easy clipping onto switch-   boards terminals.        ● Highly reliable.     ● Identifies 3 phase sequence and open phase check.● Ideal for installing conveyor lines, pump systems and     interconnected drivers.     SPECIFICATIONS             Input voltage 100-500V AC Frequency range 45-70 Hz Circuit structure All electronic (not mechanical) Power requirement 9V (6F22) × 1 Power consumption Consumption current approx. 14mA of motor rotation field tester AC power consumption Approx. 7mA Dimensions 153(L) × 72(W) × 35(D)mm Weight (battery included) Approx. 200g Safety standard EN 61010-1 CAT III 500V EN 61326-1

FEATURES ● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence.     SPECIFICATIONS       Voltage 90V-600V AC Frequency response 50 / 60 Hz Operating temperature & humidity 0°C ~ 40°C at 80% Max. relative humidity Storage temperature & humidity -10°C ~ 50°C at 90% Max. relative humidity Cord 1.1m each of red(R), white(S) and black(T) cord Dimensions 134(L) × 85(W) × 45(D)mm Weight Approx. 510g Safety standard IEC 1010 CAT II 600V

FEATURES ● Non-contact detector clips. No metal contact points to    advocate greater safety.● Two functions in one unit : open phase and phase   sequence detection.● Designed for checking a wider range of 3-phase power    sources.● LED display lights with buzzer indicator.       ● Brightness button feature for better visibility in dimly lit    areas or sunlight.● Magnetic mounting feature.     SPECIFICATIONS             Measurement principle Static induction Input voltage 75~1000Vac Frequency range 45-65Hz Auto-off 5 min. after power on without detection Low battery warning Power LED flashes at 7V ± 0.2 or less Operating temperature & humidity 0°C ~ 40°C Max. 80% R.H. Storage temperature & humidity -10°C ~ 50°C Max. 80% R.H. Cable length Approx. 800mm Dimensions 128(L) × 72(W) × 44(D)mm Weight (battery included) Approx. 380g Power source 9V (6LF22) × 1 Safety standard EN 61010-1...

FEATURES ● The 890 PR is a Non-Contact phase detector    with flashing LEDs and a beeping buzzer to    show the detection of AC 3-phase sequence.● Two functions in one unit : open phase and     phase sequence detection.● Convenient brightness switch to make the    indication visible in dim areas or sunlight.● Back cover magnet attaches the instrument to   the AC distribution panel offer easy measurement.● 3-Phase AC 75 to 1000V is fitted for detection.● Detect frequency range is from 45 to 65Hz.     SPECIFICATIONS       Measurement principle Static induction Input voltage 75~1000Vac Frequency range 45-65Hz Auto-off 5 min. after power on without detection Low battery warning Power LED flashes at 4.6±0.1V or less Operating temperature & humidity 0°C ~ 40°C Max. 80% R.H. Storage temperature & humidity -10°C ~ 50°C Max. 80% R.H. Cable length Approx. 800mm Dimensions 118(L) × 69(W) × 38(D)mm Weight (battery included) Approx. 370g ...

FEATURES ● Indicates phase rotation.        ● Indicates phase presence.● Indicates motor rotation/wiring.● Indicates battery status.● Phase rotation and motor rotation indication works from as low as 1Vac.● Small, rugged enclosure.● Color coded test leads.● Phase presence indication from as low as 100 Vac. ● Very low consumption.● Fused.      ● Lightweight, robust and compact.● Works from 2 Hz to 400 Hz Sine.     SPECIFICATIONS       Phase Presence Nominal Voltage for Phase Presence Indication (The voltage required for the neon Lamps L1, L2, L3 to light up). From To Freq 100Vac 500Vac 10-400Hz Determination of Phase Rotation Field Direction From To Freq 1Vac 500Vac 2-400Hz Determination of Motor Connections (requires > 1/2 turn of the shaft) From To Freq 1Vac 500Vac 2-400Hz Maximum Current Consumption 18mA Over Voltage CLASS III 500V Over Load between all terminals 500V Battery OK goes off when battery voltage < 6.5 Vdc Dimensions ...

FEATURES ● Indicates phase rotation.        ● Indicates phase presence.● No battery required.● Phase rotation phase presence indicated on large    liquid crystal display.● Small, rugged enclosure.● Color coded test leads.● Phase presence indication from as low as 40Vac to   as high as 500Vac.● Fused.● Lightweight, robust and compact.● EN 61010-1 CAT III 500V   EN 61010-2-032     SPECIFICATIONS       ELECTRICAL     Determination of the Phase Presence Nominal Voltage for Phase Presence Indication (the voltage required for the LCD L1, L2, L3 indicators to come on) From 40Vac to 500Vac. Frequency range From 15Hz to 400Hz. Determination of the Phases Rotary Field Direction:   Direction Indication by LCD Display(the voltage required to have the LCD Direction Arrows to indicates and the L1 L2 L3 or L3 L2 L1 indicators to show) From 40 to 500Vac. Frequency range From 15 Hz to 400Hz Protection     Over load 700V(between...

FEATURES ● The 865 PR is a detector with LEDs to show the de-    tection better visible than neon.         ● Three functions in one unit, including open phase,     phase sequence and 3 phase motor rotation.● Designed for checking a wider range of 3 phase         power source from 100V to 500V.● Indicates R.S.T LEDs which frequency range from 40Hz to 400Hz.● Wide range detection of motor frequency range from 2Hz to 400Hz.● Fixed magnets for convenient measurement.     SPECIFICATIONS       Measurement principle Contact Live Wire Input voltage 100-500Vac Frequency range 40Hz-400Hz Operating temperature & humidity 0°C ~ 40°C Max. 80% R.H. Storage temperature & humidity -10°C ~ 50°C Max. 80% R.H. Cable length Approx. 1m Dimensions 128(L) x 72(W) x 44(D)mm Weight (battery included) Approx. 220g  Power source 9V (6F22) × 1 Safety standard EN 61010-1 CAT III 500V EN 61326-1 EN 61557-1 ...

FEATURES ● Two functions in one unit: open phase and phase       sequence detection.● Neon light indicators.● Large size alligator clips for easy clipping onto switch-    boards terminals.● Allows you to check a wide range of 3-phase power     sources.● Special test leads length are available on request.     SPECIFICATIONS       Input voltage 100-500V AC Frequency range 45 - 70 Hz Circuit structure All electronic (not mechanical) AC power consumption Approx. 7mA Dimensions 102(L) × 78(W) × 32.5(D)mm Weight Approx. 228g Safety standard EN 61010-1 CAT III 500V EN 61326-1