GasDNA

  • Filter
Category: Smoke sensor

SD-50, the smoke detector with built-in micro processor, receiving signal from sensor and comparing it with preset alarming value, if it exceeds, transmits the relay output to be connected to PLC/DDC. Usually, the other smoke detectors designed only for fire alarm cannot be used for industrial use because it cannot secure enough accuracy and stability. However, SD-50 accommodating highest accurate ionization sensor and industrial detector technology, secures best accuracy and stability at the same time.

Category: Smoke sensor

SD-110 is a microprocessor internal 2-channel smoke detector. SD-110 is an environment-adaptive smoke detector which displays the concentration on the back light LCD by receiving the serial signals from two sensors and by processing them in the digital mode, and performs the variety of local functions in digital process mode. Also, it can ensure the effective remote control by stably outputting the analog serial signals to external control unit such as PLC/DDC. As one of big advantages of SD-110, it can be suitably applicable for various purposes by processing the sensible signals detected by ionization sensor by microprocessor stably and accurately. Because the existing smoke detectors have been mostly applied only for a fire alarm, it is general that they don’t ensure an accuracy and safety for a utility of industrial field. SD-110 is designed to ensure a sensibility and safety simultaneously by controlling the sensible ionization sensor with an industrial detector technology.

Category: Smoke sensor

TS-60 is built-in Non contact Infrared thermometer and smoke sensor. The most of existing temperature and smoke sensors in markets can detect fire after the heat reach to temperature and smoke detector. However, TS-60 detects the fire by increased infrared amount and low concentrated smoke in early stage of the fire and enables to prevent the fire in advance.

The thermometer is a non-contact infrared thermometer. It can measure from -60 to 550 ℃ (-76~1022 ºF) in the distance of 75:1 DS (Distance to Spot) ratio There are many mathematical modes for the Infrared function

The non-contact infrared thermometer is the ultimate tool for temperature measurements. It can measure from -35 to 1500 ℃ (-31~2732 ºF) in the distance of 75:1 DS (Distance to Spot) ratio. Furthermore, the memory mode can record and display the specific measurement with emissivity. There are many mathematical modes for the Infrared function.

The non-contact infrared thermometer is the ultimate tool for temperature measurements. It can measure from 200 to 2400 ℃ (392 to 4352 ºF) in the distance of 100:1 DS (Distance to Spot) ratio. Furthermore, the memory mode can record and display the specific measurement with emissivity. There are many mathematical modes for the Infrared function. [ Specification ] Item Non-contact Infrared Scan function Thermocouple Probe Scan function (K type; a bead wire included.) Measurement Range 200 ~ 2400℃ K type: -64 ~ +1400℃ Bead: -50 ~ +250℃ Operating Range 0 ~ 50℃ Accuracy ±2% of reading ±1% of reading or 1℃ Emissivity Range 0.1 ~ 1.0 (Default 0.95) Response Time 1 sec D:S (Distance:Spot) 100:1 Memory Detailed 24 Memories with Temperature & Emissivity Battery Life min 140 hours continuous use (Alkaline, without Laser and Back Light.) Dimensions 233.8 x 207.5 x 60.6mm Weight 550g including batteries (AA*2pcs)  

Category: Indicator

DI-20 has built-in high performance A/D converter & micro-processor which enable multi input signals, output signal transmission, communication, and alarm

Category: Gas Detector

DA-50 detects various combustible & toxic gases leaked from industrial areas for gas producers, gas users, gas reservoirs, gas by-producers, and so on, in order to prevent any accidents in advance. DA-50 converts digital signal into the 4-20㎃ standard current signal for output signal which can be transmitted to various external devices such as PLC, DDC, RECODER, and so on. Using these functions, you can easily construct the gas monitoring system more extensive as well as more comprehensive. DA-50 provides RS-485 communication signal and gas leakage alarm signal by relay contact output. Besides, DA-50 has DC 4-20mA standard output which realizes max 2,500m long distance output signal transmission from sensor to receiver and RS-485 communication signal which realizes max 1000m long distance signal transmission.