IR-20 non-contact infrared thermometer measures the infrared wavelength emitted from the target spot and converts it to standard current signal output (4~20mA). It can measure from 0 ℃ to maximum 400℃ in the distance of 10:1 D:S (Distance to Spot). Emissivity is 0.95 (fixed).

GMS-1000 is one point digital controller which can be connected to only one(1) gas detector. Receiving analogue continuous signal from one (1) detector and converting it into digital signal, GMS-1000 provides various alarming and monitoring environment by micro-processor. Also, GMS-1000 converts digital signal into the 4-20㎃ standard current signal for output signal which can be transmitted to various external devices such as PLC, DDC, RECODER, and so on. Using these functions, you can easily construct the gas monitoring system more extensive as well as more comprehensive.

The thermometer is a non-contact infrared thermometer. It can measure from -60 to 550 ℃ (-76~1022 ºF) in the distance of 75:1 DS (Distance to Spot) ratio There are many mathematical modes for the Infrared function

Category: Gas Detector

DA-50 detects various combustible & toxic gases leaked from industrial areas for gas producers, gas users, gas reservoirs, gas by-producers, and so on, in order to prevent any accidents in advance. DA-50 converts digital signal into the 4-20㎃ standard current signal for output signal which can be transmitted to various external devices such as PLC, DDC, RECODER, and so on. Using these functions, you can easily construct the gas monitoring system more extensive as well as more comprehensive. DA-50 provides RS-485 communication signal and gas leakage alarm signal by relay contact output. Besides, DA-50 has DC 4-20mA standard output which realizes max 2,500m long distance output signal transmission from sensor to receiver and RS-485 communication signal which realizes max 1000m long distance signal transmission.

Category: Indicator

DI-20 has built-in high performance A/D converter & micro-processor which enable multi input signals, output signal transmission, communication, and alarm

Category: Smoke sensor

SD-50, the smoke detector with built-in micro processor, receiving signal from sensor and comparing it with preset alarming value, if it exceeds, transmits the relay output to be connected to PLC/DDC. Usually, the other smoke detectors designed only for fire alarm cannot be used for industrial use because it cannot secure enough accuracy and stability. However, SD-50 accommodating highest accurate ionization sensor and industrial detector technology, secures best accuracy and stability at the same time.

Category: Accessories

Air purge removes dust around infrared thermometer. It can be applicable to IR-20, IR-20-4W, IR-21, IR-40, IR-80, IR-80-H, 6-IRman, 2S-IR-100, 2IGA-IR-100