By Brands

Brands

  • Filter
Category: Weather

Wind speed sensor for use with the RFPulse2000A or Pulse101A data loggers. The anemometer can be purchased stand alone or with four different cable length options. The Wind101A is also available as an entire system including the Pulse101A Data Logger, Weather Proof Enclosure, 3-Cup Anemometer, and IFC200 Software and Interface Cable Package.

True RMS 3000A Voltage Measurement (AFLEX 3002 only) Fast Peak Function(30 μs) MAX/MIN Auto-Power-Off:30 minutes Flexible probe, different from normal clamp meter, can pass through obstacles at will and wind many conducting wires simultaneously, max. diameter 170mm

The AVS150 is a complete system used to perform autoclave validations. The AVS150 consists of a N.I.S.T. traceable HiTemp150 data logger, an IP68 extended range thermal shield, an IFC200 USB cable package and MadgeTechs Secure Software and IQ/OQ/PQ validation protocols, providing tools to users to assist with FDA 21 CFR Part 11 compliance. For larger size autoclaves or mapping projects, the AVS150-5, includes five HiTemp150s and five thermal shields. The HiTemp150 is completely submersible and can measure temperatures up to 150°C. The 2" rigid probe provides a fast response time and can record readings as fast as once per second. The HiTemp150 can be used in each autoclave cycle for verification and to provide data for validation. When used with the thermal shield the device can withstand up to 250°C (time dependent).   MadgeTech's Secure Software provides data in graphical and tabular form, and provides a summary and statistical report of the data. The software also features sterilization calculations to determine the F0 value. Furthermore the software allows for different user levels and logins, electronic signatures, an audit trail and a secure data file to stand up...

Power Analysis (3005) W, KW, H.P. VA ,KVA, VAR, KVAR PF, Phase Angle( Φ ) Energy (WH, KWH) Dual displays (W+PF, VA+KVAR) Balanced 3 Φ Power Quality and Sequence Harmonics Analysis True RMS (V and A) 3000 A Non-interrupted Harmonic Analysis ( V and A ) to the 50th Order in % and Magnitude Analysis of % THD-F and C.F. Fast Peak Function (33μs and 39μs) Programmable PT (1 to 250 )ratios Auto - Power - Off : 30 Minutes

The AVS150-5 is a complete system used to perform autoclave validations. The AVS150-5 consists of five N.I.S.T. traceable HiTemp150 data loggers, five IP68 extended range thermal shields, an IFC200 USB cable package and MadgeTechs Secure Software providing tools to users to assist with FDA 21 CFR Part 11 compliance. For smaller size autoclaves or mapping projects, the AVS150, includes one HiTemp150 and one thermal shield.   The HiTemp150 is completely submersible and can measure temperatures up to 150°C. The 2" rigid probe provides a fast response time and can record readings as fast as once per second. The HiTemp150 can be used in each autoclave cycle for verification and to provide data for validation. When used with the thermal shield the device can withstand up to 250°C (time dependent).   MadgeTechs Secure Software provides data in graphical and tabular form, and provides a summary and statistical report of the data. The software also features sterilization calculations to determine the F0 value. Furthermore the software allows for different user levels and logins, electronic signatures, an audit trail and a secure data file to stand up to auditors.

Category: Anemometer

Sensitive and Accurate Ergonomic and easy-to-use design Large 4 digits LCD (Liquid Crystal Display) 1.8 meters coiled cable and mounting nut for long extension Low power consumption Hold/Max/Min/Ave functions Build-in low battery indicator Smart Auto-Power-Off (10 minutes) RS-232C Interface with PC (AVM-303) Optional Thermal Printer PROVA 300XP (AVM-303)

Display of Overlapped Voltage and Current Waveform Maximum Demand (MD in W, KW, MW) with Programmable Period Harmonics Analysis ( V and I ) to the 50th Order Display of 25 Harmonics in One Screen with Waveform Display of waveform with Peak Values (512 Samples / Period), Datalogging of 32, 64, 128 or 256 Points/Cycles Analysis of Total Harmonics Distortion ( % THD-F ) Graphic Phasor Diagram Programmable PT (1 to 3000) Ratios Capture 128 Transient Events ( Time + Cycles + Faults ) with Programmable Threshold(%), Can Also be Reviewed in LCD 50000 Records with Programmable Interval ( 1 to 6000 seconds) Output of Waveform, Power Parameters and 50 Harmonics at Command. Large Dot Matrix LCD Display with Backlight Optical Isolated RS-232C Interface Smart Datalogging to save Battery Power for Long-term Monitoring Built - in Calendar Clock for Data Logging

Category: Anemometer

Sensitive and Accurate Ergonomic and easy-to-use design Large 4 digits LCD (Liquid Crystal Display) 1.8 meters coiled cable and mounting nut for long extension Low power consumption Hold/Max/Min/Ave functions Build-in low battery indicator Smart Auto-Power-Off (10 minutes) RS-232C Interface with PC Optional Thermal Printer PROVA 300XP Air temperature measurement