By Brands

Brands

  • Filter

Best resolution 1μΩ. Accuracy 0.05% 5A (120 mΩ) max. test current. Manual or Auto Range. (There are 6 ranges of current measurement, and furthermore 3 ranges in each current range.) Measurement of resistive and inductive materials (Two terminal measurement; Four terminal Kelvin measurement) Programmable Hi-Lo alarm with memory of 20 data. Auto-judgments of Hi (readings higher than Hi-Limit), Lo (readings lower than Lo-Limit) and Pass (readings between Hi-Lo Limits). Alarm (beeper) for Hi and Lo. Readings Hold function. Cable length measurement. The length unit can be selected between Meter (M) and Feet (FT). Resistance measurement results excluding cable resistances. Memory of 3,000 measurement data. Large LCD (5-digit) with backlight (users can choose to disable it). Rechargeable batteries and AC adaptor. Low battery (voltage) alarm. Low power consumption. Communicate with PC via RS232C (to USB bridge) cable. Application: various low-resistance (cables) measurement; contact resistance measurement, …etc.

60V, 6A (PROVA 200A) 60V, 12A (PROVA 210) I-V Curve Test for Solar Cell Max. Voltage (Vmaxp) and Max. Current (Imaxp) at Max. Power (Pmax) I-V Curve with cursor Calculation of Efficiency (%)

Category: Printer

Portable Field Printing for Certificate Text and Graphics Two Selectable Fonts (5*7 and 8*16) Programmable text Header and Footer Battery and AC Power Adaptor RS-232C Interface (Optional RS-232C to USB Bridge) Fixed Interval Continuous Printing(5, 30, 60, 300 seconds)

Analysis for Single Phase and Balanced 3 phase system True RMS Value (V and I) Active Power (K,KW,MW,GW) Apparent (VA,KVA,MVA) and Reactive Power (VAR,KVAR,MVAR) Power Factor (PF), Phase Angle( Φ ) Energy (WH,KWH,KVARH,PFH) Programmable PT(1 to 3000)Ratios Display of Overlapped Voltage and Current Waveform Maximum Demand (MD in W,KW,MW) with programmable Period Harmonic Analysis (V and I) to 50th Order Display of 25 Harmonics in one screen Optical Isolated RS-232C Interface Smart Datalogging to save Battery Datalogging of 32,64,128 or 256 points/cycles Analysis of Total Harmonic Distortion (%THD-F) Graphic Phasor Diagram Capture 128 Transient Events (Time+Cycles+Faults) with Programmable Threshold(%),also can be reviewed in LCD 50000 Records with Programmable Interval (1 to 6000 seconds) Real-time Output of Waveform, Power Parameters and Harmonics at Command Large Dot Matrix LCD Display with Backlight Power for Long-term Monitoring Built -in Calendar Clock for Data Logging

Over-Voltage , Over-Current Protection Built-in Buzzer Alarm Easy RECALL and STORE functions Stby / Operate Button English-like RS-232C commands OCP With Programmable Timer 200 Sets of Memory AUTO-STEP function with programmable interval Bi-direction RS-232C interface 3.8 kg / 8.4 Lbs weight