FEATURES Multi-purpose Cable Tester ● 165 CB is an ideal tool which can test the correct pin configuration    for different kinds of cables.● For testing:    -RJ45/RJ11 -USB    -COAX -BNC cable    -Multi-wire cable● Auto-scan and manual-check function● Buzzer sound warning for wire status● 2 LED module indicators on the master unit which can    do both of transmitter and receiver functions for   RJ45/RJ11 cable testing. Users don't need to use the receiving unit.● 165 CB provides a variety for checking cable continuity,  open status, short status and miss-wired.  ● Ground (shielded ) wire test.● LED indication for wire status.● Power source : 9V batteryAmplifier Probe ● The Amplifier Probe is designed to identify and trace  wires or cables within a group without damaging the insulation.   ● The flashlight function for easier cable tracing in the dark.● An LED indication for the signal strength. ● Volume control for increased sensitivity and adjustable   to suit work environment.● Recessed...

FEATURES ● The 890 PR is a Non-Contact phase detector    with flashing LEDs and a beeping buzzer to    show the detection of AC 3-phase sequence.● Two functions in one unit : open phase and     phase sequence detection.● Convenient brightness switch to make the    indication visible in dim areas or sunlight.● Back cover magnet attaches the instrument to   the AC distribution panel offer easy measurement.● 3-Phase AC 75 to 1000V is fitted for detection.● Detect frequency range is from 45 to 65Hz.     SPECIFICATIONS       Measurement principle Static induction Input voltage 75~1000Vac Frequency range 45-65Hz Auto-off 5 min. after power on without detection Low battery warning Power LED flashes at 4.6±0.1V or less Operating temperature & humidity 0°C ~ 40°C Max. 80% R.H. Storage temperature & humidity -10°C ~ 50°C Max. 80% R.H. Cable length Approx. 800mm Dimensions 118(L) × 69(W) × 38(D)mm Weight (battery included) Approx. 370g ...

FEATURES ● Designed for measuring AC current, AC voltage resistance and DC   voltage .● Rotary scale which presents only one scale in windows at one time   to avoid any possible reading errors.● Pointer lock function freezes the reading in dimly lit or hard to reach   places.● Ω range ideal for checking the continuity or relays, transformers and   motor coils.     SPECIFICATIONS         AC A 6 / 15 / 60 / 150 / 300A ±3% of F.S.(50/60Hz) AC V 300 / 600V ±3% of F.S. DC V 75V ±3% of F.S.   Ω 2kΩ ±3% of Scale length Frequency response 50 / 60Hz for ACA 6A 50-400Hz for ACA 15 / 60 / 150 / 300A Dimensions 230(L) × 72(W) × 37(D)mm Conductor size 38mm Max. Weight (battery Included) Approx. 420g Safety standard EN 61010-1 CAT II 600V EN 61010-2-32

FEATURES ● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Fuse protection function.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● hFE and db measurement.● With stand...makes reading and measuring easy.     SPECIFICATIONS         DC volts 0-0.1 / 0.5 / 2.5 / 10 / 50 / 250 / 1000V(20kΩ/V) AC volts 0-10 / 50 / 250 / 1000V DC mA 50uA / 2.5 / 25 / 250mA OHMS 2k / 20k / 2M / 20MΩ (20 Mid-Scale) Accuracy ±3% F.S. DC. ± 4% F.S. AC. Sensitivity 20kΩ/V DC. 8kΩ/V AC. dB -10 to ± 50dB hFE 0-1000 ICEO 150uA, 15mA, 150mA LV 3V Dimensions 102(L) × 148(W) × 46(D)mm Weight (battery included) Approx. 300g  Power source 1.5V (AA) × 2 9V(6F22) × 1 Safety standard IEC 1010-1 CAT II 1000V

FEATURES ● Microprocessor-controlled.● Four terminal measurement.● Measures down to 100μΩ.● 5 Ranges from 200.0mΩ to 2000Ω.● Maximum resolution of 100μΩ.● Three test currents with over-temperature protection.● Protection against inadvertent connection to over voltage.● Large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave inside.● EnerSave Auto hold.● EnerSave Auto off.● Lightweight, robust & compact.● Indicators show if reading may be invalid (RP, RC, and     temperature).● "O-Ring” sealed case.     SPECIFICATIONS         Measuring ranges 0-200.0mΩ in steps of 100μΩ 0-2000mΩ in steps of 1mΩ 0-20.00Ω in steps of 10mΩ 0-200.0Ω in steps of 100mΩ 0-2000Ω in steps of 1Ω Accuracy ±0.5% of reading ±2 digits over the operating temperature range, -15ºC to +55ºC, with the supplied test leads Test current 1mA=>2000Ω range 10mA=>200 / 20Ω ranges 100mA=>2000m / 200mΩ ranges Test current accuracy ±0.1% Protection fuses Mains = 0.5A,...

FEATURES ● Input Voltage : 120V AC or 240V AC.● Standard 4.5-inch switchboard case.● Front panel mount.● 3 bi-colored LED indicators for "SYNC", "GEN" and "BUS".● 24 LEDs in a circle display the phase angle and the frequency differences between 2 networks.● 360° LED indication.● 12 o'clock position LED is bi-colored.     SPECIFICATIONS          LS-110 SYNC  (120V)   LS-110 SYNC (240V) Nominal Input Voltage 120V AC 240V AC Overload 1.25 × Nominal voltage Frequency Range 35~70Hz Scale SLOW / FAST Pointer LED 15 degrees / LED BUS LED (Bi-colored) Green :108V-132V AC Green :216V-264V AC Red :<108V   or   >132V AC Red :<216V   or   >264V AC GEN LED (Bi-colored) Green :108V-132V AC Green :216V-264V AC Red :<108V   or   >132V AC Red :<216V   or   >264V AC SYNC LED (Bi-colored) Green :"GEN" and "BUS" are...

Category: Test Leads

Wire : PVC UL 1803 / 18AWG.     length : 1100±30mm    Out diameter : 3.50mm    Temperature tolerance range : -40ºC~105ºC    Braid copper wires : 64 / 0.12mm● Terminal :    Right angle 4mm brass (nickel plated) banana plug with    caged and insulated sheathing to avoid the brass oxidation.● Rating :    EN 61010-031:2002 + A1:2008    CAT III 1000V 10A / CAT IV 600V 10A

Category: Multimeter

0.5% Accuracy. Overload Fuse protection. Test Clips/Direct insert jack for easy measurement.