  • Filter

Electromagnetic Conductivity Transmitter MDM-135A (2-wire) Electromagnetic conductivity analyzer for field installation in a compact and rigid aluminum enclosure  Made for accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali) Alterable output range Meas. range Minimum : 0 - 2 mS/cm Maximum : 0 - 2000 mS/cm

Panel type DO analyzer in a compact DIN 96 size One-touch calibration and various self-diagnostic functions 2-point contacts signal, 4 - 20mA output (RS-232 optional)  Power supply: 90 - 264VAC, 50/60Hz Meas. range Minimum : 0 - 1 mg/L Maximum: 0 - 50 mg/L

Process analyzer for automating analytical techniques such as atomic absorption and etc. Suitable for automating chemical analysis processes such as distillation, heat treatment, etc. Example applications:  *Total chromium  *Total cyanide by atomic absorption/distillation  *Phenols by atomic absorption/distillation  *Total mercury by oxidation-reduction atomic absorption

B4 size compact analyzer excellent in reliability, durability and maintainability Enables continuously measurement of turbidity, color, residual chlorine, pH, conductivity, temperature and pressure without reagents Equipped with interactive easy-to-use color touch panel

A complete sampling system composed with cooler, pressure reducer, valves, flowmeter and thermostat chambers Enables sampling for analysis from the boiler Consistent manufacturing from analyzer to sampler Sample condition Maximum temperature: 600 degrees C Maximum pressure: 30 MPa Maximum flow rate: 3 L/min

Designed for oil refinery  Automatic fractional distillate analyzer of batch distillation type enables distillation test of petroleum products such as kerosene, diesel oil, gasoline and etc. Adopts high resolution liquid level detecting sensor Newly-developed FA computer embedded with large-sized, color touch panel Explosion-proof TIIS fd2G4 certified Meas. range Standard:Light gas oil (0 - 400 degrees C), Kerosene (0 - 300 degrees C), Gasoline (0 - 200degrees C)

Automated Total Nitrogen/Phosphorus/COD Analyzer NPW-160 Measuring based on official measuring method Multiple-wavelength detector enables measurement of total nitrogen, total phosphorus and COD simultaneously Space-saving design attained by eliminating back piping Drip-proof construction Meas. range Total nitrogen: 0 - 2 mg/L to 50 mg/L Total phosphorus: 0 - 0.5mg/L to 20 mg/L COD (UV method): 0 - 2 Abs

PM2.5 Monitor FPM-377 Environment Ministry (JAPAN) Approval Beta ray attenuation method (mass concentration) Heater type dehumidifier VSC cyclone (USEPA approval) Outdoor type and indoor type available  Meas. range 0 - 500, 0 - 1000, 0 - 5000 μg/m3