FEATURES ● Microprocessor-controlled.● 2 Lines × 16 Characters LCD.● Very low consumption.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity Shown on LCD.● Auto off and off override.● Polarity Trip indicator (Positive or Negative Phase).● Wiring polarity indicator.● Measure voltage between line and earth before testing.● Indicates frequency of voltage L-E.     SPECIFICATIONS         Current settings 3mA, 5mA, 7mA, 10mA, 15mA, 20mA, 30mA, 35mA, 50mA, 100mA, 125mA, 150mA, 175mA, 250mA, 300mA, 375mA, 500mA. Current selection Rotary switch Phase start selection 0° and 180° Referenced to Earth Yes Over-temperature protection Yes Wiring correctness indication Yes Trip indicator Yes Phase polarity trip Indicator Yes Operating voltage (L-E) Referenced to Earth 240Vac-50Hz or 60Hz Voltage Model (Vac) Timer resolution 1ms (Max. Time=19.99s) Timer accuracy 1ms...

FEATURES ● Microprocessor technology ensures high    performance accuracy and reliability.● Fully programmable via tactile key pad.● Direct readout of disconnection, time or current. ● Voltage measured during test.● Housed in a heavy duty carry case.● Suitable for all industrial, mining and domestic     environments.● Display can be customized for special orders.● Indicate voltage and trip Current/Time.● Use binary principle.● True resistor switching.     SPECIFICATIONS       Rated tripping current at 317V 1000mA (2000mA on special orders) Lowest resolution 1mA System voltage 230 / 380 / 550V (50Hz) Maximum trip time 99.99s Highest resolution 10ms Typical Accuracy Rated trip current ±1%rdg ± 2dgt Voltage range ±1%rdg ± 1dgt Trip-time ±1%rdg ± 2dgt Voltage 0°C to 40°C Operating-humidity 80% Max. relative humidity Dimensions 330(L) × 260(W) × 160(D)mm Weight (battery included) Approx. 3700g Power source 1.5V “C” × 8...

FEATURES ● Microprocessor-controlled.● Indicates phase rotation.● Indicates phase presence.● Tests for disconnection sensitivity.● Indicates battery status.● Tests for disconnection time.● Measures voltage phase to earth.● Select one of 3 Phase to test ELCB.● Color-coded test leads.● Phase presence indication from as low as 100Vac.● Very low consumption.● Fused earth leakage tester.● ELCB works 50Vac to 330Vac 50Hz / 60Hz.● Led indication of Voltage on ELCB.● Phase rotation and presence does not require battery to indicate.● EN 61010-1 CAT III 550V. EN 61326-1     SPECIFICATIONS     Determination of the Phase Presence     Nominal Voltage for Phase Presence Indication (the voltage required for the neon lamps L1, L2, L3 to lit up) From 100Vac to 450Vac. Frequency Range From 10Hz to 400Hz. Determination of the Phases Rotary Field Direction   Direction (the voltage required to have the direction LEDs L1-L2-L3 or L2-L1-L3 to indicates) From 100 to 450Vac. Frequency Range From 2Hz to...

FEATURES ● Wiring check.● Can be used on 2 wires L-E (ELCB/RCCB/GFCI tester).● Can be used on 3 wires L-E-N (with wiring check).● Sense automatically 50 or 60 Hz.● No battery required.● Simple operation.● Current injected in phase with the voltage.● Fused.● Wide operating voltage (195Vac to 265Vac).● Other voltage optional (110V).● Robust.     SPECIFICATIONS         Wiring check LEDs Line-Neutral = Green Line-Earth = Green Neutral-Earth =Red Current settings 10-50mA@230Vac> Current selection Knob Frequency of operation 50/60 Hz Sinusoidal Over-Temperature Protection Yes by NTC sensor Test stopped indication by Red Led. Operating voltage (L-E) 230 Vac ±15% Meter accuracy ±3% of full scale Operating temperature -5°C to 45°C Storage temperature -10°C to 55°C Dimensions 150(L) × 73(W) × 50(D)mm Weight Approx. 220g Safety standard EN 61010-1 CAT III 265V EN 61326-1

FEATURES ● Taut Band movement.● Simple operation.● Wiring check.● Robust.● Can be used on 2 wires L-E (ELCB/RCCB/GFCI tester).● Can be used on 3 wires L-E-N (with wiring check).● No battery required.● Sense automatically 50 or 60 Hz.● Current injected in phase with the voltage.● Other voltage optional (110V).     SPECIFICATIONS             Current settings 10-50mA@230Vac> Current selection Knob Frequency of operation 50/60 Hz Sinusoidal Over-Temperature Protection NO Operating voltage (L-E) 230 Vac ±15% Meter accuracy ±1% of full scale Protection Fused (200mA 250V) Operating temperature -5°C to 45°C Storage temperature -10°C to 55°C Dimensions 170(L) × 165(W) × 92(D)mm Weight Approx. 730g Safety standard EN 50081-1 EN 50082-1