SEW-Taiwan

Various Instruments

  • Filter

FEATURES ● Designed to proof.   AC voltage detectors   AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.     SPECIFICATIONS Output voltage H terminal: AC 400V (± 20%) L terminal: AC 100V (± 20%) Frequency 50-60Hz Power on indicator   ˇ Operating temperature 0°C ~ 40°C Dimensions 124(L) × 69(W) × 42(D)mm Weight (battery included) Approx. 305g Power source 9V(6F22) × 1 Safety standard EN 61010-1 EN 61326-1

FEATURES ● Microprocessor-controlled.● Four terminal measurement.● Measures down to 100μΩ.● 5 Ranges from 200.0mΩ to 2000Ω.● Maximum resolution of 100μΩ.● Three test currents with over-temperature protection.● Protection against inadvertent connection to over voltage.● Large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave inside.● EnerSave Auto hold.● EnerSave Auto off.● Lightweight, robust & compact.● Indicators show if reading may be invalid (RP, RC, and     temperature).● "O-Ring” sealed case.     SPECIFICATIONS         Measuring ranges 0-200.0mΩ in steps of 100μΩ 0-2000mΩ in steps of 1mΩ 0-20.00Ω in steps of 10mΩ 0-200.0Ω in steps of 100mΩ 0-2000Ω in steps of 1Ω Accuracy ±0.5% of reading ±2 digits over the operating temperature range, -15ºC to +55ºC, with the supplied test leads Test current 1mA=>2000Ω range 10mA=>200 / 20Ω ranges 100mA=>2000m / 200mΩ ranges Test current accuracy ±0.1% Protection fuses Mains = 0.5A,...

FEATURES ● High quality movement.● Compact and lightweight; easy to use and store.● Mirror scale: for easier viewing & reading.● Built-in stand makes reading and measuring easy.● 200μA full scale value.● Fuse-protected.● Low battery indication.     SPECIFICATIONS   AC Leakage Current     Measuring range 0.3mA-1mA-3mA-10mA-30mA Accuracy ±2% of full scale Input resistance 1.5kΩ / 2kΩ AC Voltage     Measuring range 0-150 / 0-300V Accuracy ±2% of full scale Input resistance 150V     500kΩ 300V     1MΩ General     Low battery indication Battery check indicate good battery from 7Vdc to 9Vdc during a load test of 2mA Dimensions 160(L) × 100(W) × 45(D)mm Weight (battery included) Approx. 370g Power source 9V(6F22) × 1 Safety standard EN 61010-1 CAT III 600V EN 61326-1

FEATURES ● Microprocessor-controlled smart voltage detector.● Bright LED and audible alarm sound when voltage is present.● Designed for non-contact voltage detection.● Sensitivity adjustable with thumbwheel.● Adjustable for use on power wiring plus lighting, thermostats and    other low voltage circuits.● LED indication for battery condition.● Identify Hot and Neutral.     SPECIFICATIONS       Voltage detection 50V~1000V AC Frequency 50~500 Hz Measurement category CAT IV 1000V Indication LED and Tone Operating conditions Temperature : 0~40°C Humidity : Less than 80% R.H. Altitude : 2000m maximum For indoor use only ˇ Pollution degree 2 Dimensions 142(L) × 28(W) × 27(D)mm Weight (battery included) Approx. 39g    Power source    1.5V (AAA) × 1 Safety standard EN 61010-1 CAT IV 1000V EN 61326-1

FEATURES ● Voltage test: 12V to 690V AC/DC (7 LEDs) with indication by   buzzer.● Voltage range: 12V, 24V, 50V, 127V, 230V, 400V, 690V.● Polarity test: LED +/-● Audible continuity test● Self-test button to ensure proper function of the device prior to   testing.● Waterproof design, protection class: IP54● Phase / Neutral identification● Integrated storage clips for test probe.● Rubberized injection molding.     SPECIFICATIONS       Voltage test 12V to 690V AC/DC Voltage range AC : 12V,24V,50V,127V,230V,400V,690V DC : 12V,24V,50V,127V,230V,400V,690V Flashlight   ˇ Working frequency 40 to 400 Hz Voltage protection 1000V DC / 700V AC Continuity range 6kΩ Resistance range 6kΩ,60kΩ,300kΩ Operating temperature 0℃ to 40℃ Operating humidity 80% R.H. Probe distance 19mm apart Dimensions   195(L) x 56(W) x 35(D)mm Weight (battery included) Approx. 214g Power source 9V(6F22) x 1 Safety standard EN 61010-1 CAT III 600V EN 61243-3 EN...

FEATURES ● 190 CBI is an easy tool to find the circuit breaker or fuse supplying    electrical power to an outlet or lighting fixture. Just plug the    transmitter into the outlet.● Use the receiver to scan the circuit breaker panel box. An audible    tone will be clearly heard when the right circuit breaker is scanned.● The plug of transmitter is changeable. The plug of transmitter could    be changed for customers' requirement from different countries.     SPECIFICATIONS       Operation voltage 110~120 VAC Operation frequency 50 / 60 Hz Transmitter power Powered by wall outlet Receiver power 9V(6F22) × 1 Safety standard EN 61010-1 EN 61326-1

FEATURES ● Large LCD : 68 × 34mm(2.677" × 1.338").● True measurement of speaker systems actural impedance at 1kHz.● Three test ranges allow testing of home theater and commercial   sound systems.● Measures transformer impedances.● Battery operation.● Low battery indication.● Data hold function.● 0Ω adjustment.     SPECIFICATIONS       Measuring ranges 0-200Ω / 0-2kΩ / 0-20kΩ Test frequency 1kHz Accuracy 200Ω/2kΩ : ±2%rdg±2dgt 20kΩ : ±3%rdg±2dgt Low battery indication “  “ Symbol appears on the display Data hold indication “   “ Symbol appears on the display Dimensions 175(L) × 85(W) × 75(D)mm Weight (battery included) Approx. 600g Power source 1.5V (AA) × 8 Safety standard EN 61010-1 CAT III 200V EN 61326-1

FEATURES ● x10 Model allows for more accurate   measurements of low amperage devices.● Direct reading x1 mode.● 4mm Voltmeter input jacks.● Intergrated ground conductor.● 10 amp capacity.● 10cm plug cord for greater flexibility.     SPECIFICATIONS         Input plug US / Europe Output socket 3 prong U.S. standard Cord length 10cm Max. Voltage/Ampere rating 120Vac(±10%)/10Aac For ETL (UL 61010-1) 250Vac(±10%)/10A For CE (EN 61010-1) Operating Temperature & Relative Humidity 0℃~50℃ Max.80%R.H. Weight Approx. 135g Dimensions 145(L)x55(W)x35(H)mm