  • Filter

FEATURES ● x10 Model allows for more accurate   measurements of low amperage devices.● Direct reading x1 mode.● 4mm Voltmeter input jacks.● Intergrated ground conductor.● 10 amp capacity.     SPECIFICATIONS       Input/Output line connector 3 prong U.S. standard Max. Voltage/Ampere rating 120Vac(±10%)/10Aac Operating Temperature & Relative Humidity 0℃~50℃ Max.80%R.H. Weight Approx. 110g Dimensions 145(L) x 55(W) x 35(D)mm

FEATURES ● x10 Model allows for more accurate   measurements of low amperage devices.● Direct reading x1 mode.● 4mm Voltmeter input jacks.● Intergrated ground conductor.● 10 amp capacity.● 10cm plug cord for greater flexibility.     SPECIFICATIONS         Input plug US / Europe Output socket 3 prong U.S. standard Cord length 10cm Max. Voltage/Ampere rating 120Vac(±10%)/10Aac For ETL (UL 61010-1) 250Vac(±10%)/10A For CE (EN 61010-1) Operating Temperature & Relative Humidity 0℃~50℃ Max.80%R.H. Weight Approx. 135g Dimensions 145(L)x55(W)x35(H)mm

FEATURES ● 2000 counts.● DC Voltage measurement.● 4-wire resistance measurement.● Data hold function.● Low battery indication.● 9V DC power supply.● Measure battery types: Li-ion, Ni-Cd, Ni-MH● Simple operation.● Lead resistance and contact resistance eliminated.     SPECIFICATIONS       DC Voltage       Range 2V 20V 100V Resolution 1mV 10mV 100mV Accuracy ±(1%rdg+1dgt) ±(1%rdg+1dgt) ±(1%rdg+1dgt) Resistance       Range 200mΩ 2000mΩ 20Ω Resolution 0.1mΩ 1mΩ 10mΩ Accuracy ±(3%rdg+3dgt) ±(3%rdg+3dgt) ±(3%rdg+3 dgt) General       Low battery indication "  " sign appears on the display when the battery voltage drops below accurate operating level. Dimensions 192(L) × 88.6(W) × 45.2(D)mm Weight (battery included) Approx. 360g Power source 9V(6F22) × 1 Safety standard EN 61010-1 CAT I 100V EN...

FEATURES ● The RCB-1 is used to verify and proof any High Voltage Insulation   Testers. It can be utilized to calibrate all High Voltage Insulation   Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator   too, therefore, SEW started manufacturing the RCB for special   customers.     SPECIFICATIONS         Resistance ranges (Ω) 1M. 2M. 7M. 10M. 20M. 30M. 50M. 100M. 200M. 500M. 1G. 2G. 5G. 10G. 20G. 50G. 100G. 200G. 500G Resistance tolerances ±1%(F) Tolerance ± 25ppm/°C : 1MΩ. 2MΩ. 7MΩ. 10MΩ. 20MΩ. 30MΩ. 50MΩ. 100MΩ. 200MΩ. 500MΩ ± 100ppm/°C : 1GΩ. 2GΩ.  ± 200ppm/°C : 5GΩ. 10GΩ. 20GΩ. 50GΩ. 100GΩ.  ± 400ppm/°C : 200GΩ. 500GΩ ± 1000ppm/°C : 1TΩ Max. working voltage DC 10kV Operating temperature -30°C~75°C Power coefficient Below 3W Connecting terminals Binding Post : Resistance circuit and guard Dimensions 430(L) × 324(W) × 127(D)mm Weight Approx. 5200g...

FEATURES ● The RCB-3 is used to verify and proof any High Voltage Insulation   Testers. It can be utilized to calibrate all High Voltage Insulation   Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator   too, therefore, SEW started manufacturing the RCB for special   customers.     SPECIFICATIONS         Resistance ranges (Ω) 1M. 10M. 100M. 1G. 5G. 10G. 100G. 500G Resistance tolerances ±1%(F) Tolerance ± 25ppm/°C : 1MΩ. 2MΩ. 7MΩ. 10MΩ. 20MΩ. 30MΩ. 50MΩ. 100MΩ. 200MΩ. 500MΩ ± 100ppm/°C : 1GΩ. 2GΩ.  ± 200ppm/°C : 5GΩ. 10GΩ. 20GΩ. 50GΩ. 100GΩ.  ± 400ppm/°C : 200GΩ. 500GΩ ± 1000ppm/°C : 1TΩ Max. working voltage DC 10kV Operating temperature -30°C~75°C Power coefficient Below 3W Connecting terminals Binding Post : Resistance circuit and guard Dimensions 430(L) × 324(W) × 127(D)mm Weight Approx. 4140g

FEATURES ● The RCB-3-1T is used to verify and proof any High Voltage    Insulation Testers. It can be utilized to calibrate all High Voltage    Insulation Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator    too, therefore, SEW started manufacturing the RCB for special    customers.     SPECIFICATIONS Resistance ranges (Ω) 1M. 10M. 100M. 1G. 5G. 10G. 100G. 1T Resistance tolerances ±1%(F) Tolerance  ± 25ppm/°C : 1MΩ. 2MΩ. 7MΩ. 10MΩ. 20MΩ. 30MΩ. 50MΩ. 100MΩ. 200MΩ. 500MΩ ± 100ppm/°C : 1GΩ. 2GΩ.  ± 200ppm/°C : 5GΩ. 10GΩ. 20GΩ. 50GΩ. 100GΩ.  ± 400ppm/°C : 200GΩ. 500GΩ ± 1000ppm/°C : 1TΩ Max. working voltage DC 10kV Operating temperature -30°C~75°C Power coefficient Below 3W Connecting terminals Binding Post : Resistance circuit and guard Dimensions 430(L) × 324(W) × 127(D)mm Weight Approx. 4140g

FEATURES ● The RCB-3-1T is used to verify and proof any High Voltage    Insulation Testers. It can be utilized to calibrate all High Voltage    Insulation Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator    too, therefore, SEW started manufacturing the RCB for special    customers.     SPECIFICATIONS Resistance ranges (Ω) 1M. 10M. 100M. 1G. 10G. 100G. 1T Resistance tolerances ±1%(F) Tolerance  ± 25ppm/°C : 1MΩ. 2MΩ. 7MΩ. 10MΩ. 20MΩ. 30MΩ. 50MΩ. 100MΩ. 200MΩ. 500MΩ ± 100ppm/°C : 1GΩ. 2GΩ.  ± 200ppm/°C : 10GΩ. 20GΩ. 50GΩ. 100GΩ.  ± 400ppm/°C : 200GΩ. 500GΩ ± 1000ppm/°C : 1TΩ Max. working voltage DC 10kV Operating temperature -30°C~75°C Power coefficient Below 3W Connecting terminals Binding Post : Resistance circuit and guard Dimensions 430(L) × 324(W) × 127(D)mm Weight Approx. 4140g

FEATURES ● The ITC 8 can be utilized to check calibration of resistance ranges   of insulation testers and multimeters.● The resistance checker box is also used to verify insulation testers   and multimeters.     SPECIFICATIONS         Resistance Ranges    0.5Ω, 1Ω, 2Ω, 20Ω, 200Ω, 1kΩ, 10kΩ,    20kΩ, 100kΩ, 1MΩ, 2MΩ, 10MΩ Accuracy    0.5Ω - 2Ω : ± 0.05Ω   20Ω - 10MΩ : ±1% Dimensions 150(L) x 72(W) x 60(D)mm Weight Approx. 180g Safety Standard EN 61010-1 CAT III 1000Vdc