SEW-Taiwan

SEW New

  • Filter

● Telescopic, compact, lightweight.● High voltage detection.● Self test button feature.● Easy to recognize indication.● High intensity red light emitting diode and intermittent audible sound    for easy recognition in full sunlight and noisy environments.● Waterproof.

FEATURES ● Max. & Min. function.● Over & under range indication.● 4-digit LCD with bar graph.● Frequency weighting characteristic for 2 times per second.● AC signal output.● Low battery indication.     SPECIFICATIONS         Measuring ranges Lo :   30dB~80dB Med : 50dB~100dB Hi :   80dB~130dB Accuracy ± 1.5dB(at Reference Range) Reference sound level & frequency 94dB, 1kHz Resolution 0.1dB Detector-indicator characteristic Fast : 125ms Slow : 1s Analogue signal output AC 1Vrms for each range Dimensions 235(L) x 58.4(W) x 34(D)mm Weight (battery included) Approx. 220g Power source 9V(6F22) × 1 Safety standard   IEC 651 Type 2 &   ANIS S1.4 Type 2  EN 61326-1

Category: Light Meter

FEATURES ● Wide range for measurements up 40000 lux and 4000 fc.● 0.01 lux and 0.001 fc resolution for accurate low light level   measurements.● Light sensor cover is included for preserving sensor life.● Auto off function.● Data hold and peak hold function.● Low battery indication.● Over range indication.● Auto-ranged.● Manual-ranged.● Calibration mode is provided.● 9V battery system.● Selection key for lux and fc.● The spectral sensitivity close to CIE photopic curve.● Ideal tool for workplace, clean-room and computer room light   testing.● Video, photographic, office, classroom, and architectural uses.     SPECIFICATIONS         Measuring ranges 39.99 / 399.9 / 3999 / 39990 lux 3.999 / 39.99 / 399.9 / 3999fc Resolution 0.01 lux - 10 lux 0.001 fc - 1 fc Accuracy ±(3%rdg+5dgt) Calibrated to standard incandescent lamp, 2856°K. Display 4000 count LCD Photo sensor Silicon photodiode Operating / storage conditions 0°C - 40°C < 80 % R.H. -10°C - 50°C < 80 % R.H. Dimensions 194(L) x...

FEATURES ● 4000 counts.● Voltage measurement, current measurement, resistor    measurement, frequency counter, capacitor measurement.● Bargraph indication.● Range change function.● Data hold function freezes the reading.● REL function.● Peak function.● VAHz mode measures frequency in ACV and ACA mode.● Diode measurement.● Max / Min function.● Continuity check.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal    parts, shielded banana plugs and recessed input terminals.     SPECIFICATIONS       DC Voltage     Ranges Resolution Accuracy 400mV 0.1mV ±(1.0%rdg+3dgt) 4V 1mV 40V 10mV 400V 100mV 600V 1V  ․Overload protection : 650V DC AC Voltage     Ranges Resolution Accuracy 400mV 0.1mV ±(0.5%rdg+3dgt) 4V 1mV ±(1.5%rdg+3dgt) 40V 10mV 400V ...

● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● Test leads are supplied as standard accessories    for simplified two-wire measuring system.● Battery operated.● Battery check function. ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-10Ω / 0-100Ω / 0-1000Ω Earth voltage 0-30 Vac (40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx Open circuit indication LED will be unlit Dimensions 205(L) × 90(W) × 55(D)mm Weight (battery included) Approx. 514g Power source 1.5V (AA) × 6 Safety standards EN 61010-1 CAT III 30V EN 61326-1

FEATURES ● True measurement of speaker systems actual impedance at 1kHz.● Three test ranges (20Ω / 200Ω / 2000Ω) allow testing of home    theater and commercial sound systems.● Measures transformer impedances.● Battery operated.● Low battery indication.● Data hold function.● Timer function for continuous hands free operation.● The timer can last about 3-5 minutes when users press.● TEST ON/OFF button.     SPECIFICATIONS       Measuring ranges 0-20Ω / 0-200Ω / 0-2000Ω Test frequency 1kHz Accuracy 20Ω : ± 2%rdg±2dgt or ± 0.1Ω, which is greater 200Ω / 2000Ω : ± 2%rdg±2dgt Low battery indiction “  “ Symbol appears on the display Data hold indiction “  “ Symbol appears on the display Display LCD 3½ digit (2000 counts) Dimensions 205(L) × 90(W) × 55(D)mm Weight (battery included) Approx. 530g Power source 1.5V (AA) × 6 Safety standard EN 61010-1 CAT III 300V EN 61326-1

FEATURES ● Microprocessor-controlled.● 2 Lines × 16 characters LCD.● Very low consumption.● 50Hz and 60Hz operation.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Over temperature protection.● Over voltage protection.● Fuse protection.● Zero crossing circuitry permit testing at 0° or 180°.● Disconnection phase polarity shown on LCD display.● Auto off and off override.● Polarity trip indicator (positive or negative phase)● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● Frequency measurement indication.     SPECIFICATIONS       Operating voltage (L-E) (50Hz or 60 Hz) Version A : 240 Vac Version B : 230 Vac Version C : 220 Vac Version D : 110 Vac Current settings 3mA, 5mA, 10mA, 15mA, 20mA, 30mA, 50mA, 100mA, 150mA, 250mA, 300mA, 500mA. Current selection Rotary switch selector Phase angle setting 0° and 180° selectable Wiring correctness indication Yes (LEDs) Trip indicator Yes (LCD) Phase polarity trip indicator Yes...

Designed to proof:     -Phasing sticks.     -High voltage detectors (contact type only, not to be used with non contact proximity detectors.)     -High voltage and voltage testers.● Battery operated.● Led indicates when power is “ON”.● Small and hand-held.● Quick connection with normal 4mm test leads.