Category: Earth Testers

Earth Clamp Tester The earth resistance from 0.05 to 1200Ω can be measured without the auxiliary earth spikes.(The Multiple Earthing System.) • True RMSAccurate true RMS readings of AC current including distorted waveform from 1mA to 30.0A • Noise Check Function A function to detect current, which effects on an earth resistance measurement and display "NOISE" mark on the LCD. • Memory function Save and display up to 100 measurement data. • Data hold function / Buzzer function / Back light function • Compliant with Safety Standards of IEC 61010-1 : CAT.IV 300V Pollution degree2   Note:A single earthing can not be measured. (Only for Multiple Earthing System)

Category: Earth Testers

Earth Clamp Tester Various useful functions are available on Android devices using Bluetooth communication   Free Android software "KEW smart 4202"is available on "Google Play Store" (*) Supporting Android ver. 2.2 - 4.2 WVGA (800 × 480) resolution or higher (*) Please search "KEW Smart" in Google Play Store.Communication charge may be incurred separately to download application.   • Real time measurements can be transferred, shown and saved on Android device (up to 100 measurements) • Saved data includes measurement, GPS location and date & timeEasy to check on map "When" and "Where" the measurement was made • Comparator function on Android device informs when the measured value is lower/higher than the preset value

Anti-Trip Technology for complete trip free Loop testing on all RCDs rated 30mA and above. • Dual Display allows simultaneous measurements like Loop & PFC/PSC. • Two wire connection for Loop L-L, L-N and PSC testing is possible. • Phase rotation, Voltage and Frequency measurements. • Lock-down test button for 'hands free' testing with auto-start operation.

Custom microprocessor controlled for highest accuracy and reliability. • 3 LEDs for checking correct wiring status. • 15mA LOOP measurement:LOOP impedance 2000Ω range measurement is carried out with low test current (15mA).The current will not cause tripping out involved RCD even the one with the lowest nominal differential current (30mA). • Direct reading of Prospective Short Circuit Current (PSC). • Safe voltage measurement function. • Large custom digital display readout on all models. • Measure low loop resistances(resolution of 0.01Ω) • Automatic lock-out if test resister overheats. • Large custom digital display readout . • Visual indication of reversed phase and neutral wiring at socket. • Designed to IP54 Rating • Complies with IEC 61557

Category: RCD Tester

Measurement of RCD trip timeConducting testing of rated residual non-operating currents at × 1/2 Range, measuring RCD trip time at × 1 and × 5 Ranges. • Measurement of trip out currentMeasuring trip out current by varying current automatically. • Remote TestEnabling a user to hold the Test Leads with his both hands by locking the Test Button. Measurement will automatically start when the main voltage is detected. • Voltage MeasurementCarrying out a constant measurement of voltage in the stand-by mode at each Range.

Category: RCD Tester

Custom microprocessor controlled for highest accuracy and reliability. • 3 LEDs for checking correct wiring status. • 0 and 180 degree phase angle switch permits quick tests and consistent readings. • Digital read-out of tripping time. • Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings. • Large custom digital display readout. • Visual indication of reversed phase and neutral wiring at socket. • Designed to IP54 Rating. • Complies with IEC 61557

Category: RCD Tester

Accurate digital readout of tripping time. • Two neon lamps give quick check for correct wiring. • Compact, lightweight and simple to operate. • Zero cross circuitry permits testing at 0 and 180 degree portion of sine wave. At these two tests minimum (best) and maximum (worst) trip times will be displayed.

Continuity Measurement Continuous testing can be carried out by use of the test button lockdown feature. A selectable buzzer gives instantaneous indication of continuity. Null facility eliminates the test lead resistance from the results, the nulled value is retained even if the instrument is switched off. Live circuit warnings are given by a flashing LED, buzzer and indication on the display. Insulation Measurement Three selectable test voltages 250V, 500V and 1000V. An auto-discharge function ensures that circuits are not hazardous after testing. A red LED gives warning of high voltage output during testing and discharging of the circuit. In case of connecting to a live circuit, a live circuit warning is given by flashing LED, buzzer and indication on the display. Loop Impedance Measurement A patented (ATT) low current loop impedance test enables high accuracy loop measurements and quick testing without tripping RCD's. A high current alternative is selectable for even higher accuracy and instantaneous results. The subsequent test will default to the low current test, this saves any inadvertent tripping of the RCD. The KEW...