By Brands

Brands

  • Filter

FEATURES ● Mains wiring polarity check.● ELCB/RCD testing.● Measuring ear for line current.● Measuring ear for leakage current.● Helps calculate insulation resistance.● Helps calculate power consumption.● Helps fault finding of standing earth fault.● Fused main adapter.● Appliance testing (with the aid of a clamp meter).● Fused appliance socket.● No batteries required.● HRC fuse inside.● Fused, color-coded universal test sockets.● Universal mains IEC Lead.     SPECIFICATIONS       Voltage / power input     Universal IEC LEAD 240V/10A Wiring polarity check     Nominal Voltage 240Vac Frequency 50/60Hz Mains Voltage Tolerance ±10% Elcb / rcd tester     Nominal Voltage 240Vac Frequency 50/60Hz Current Tolerance (current proportional to Line to Earth Voltage) ±10% Universal test sockets     Nominal Voltage 240Vac Frequency 50/60Hz Mains Voltage Tolerance ±10% Fuse 10A Appliance tester     Nominal...

FEATURES ● Bright LED and audible alarm sound when voltage is present.● Designed for non-contact voltage detection.● Can be used to find a break in a wire.● Flashlight function.● ON/OFF switch for longer battery life.     SPECIFICATIONS       Voltage detection 50V~1000V AC Frequency 50~500 Hz Measurement category CAT III 600V Indication LED and Tone Operating conditions Temperature : 0~40°C Humidity : Less than 80% R.H. Altitude : 2000m maximum For indoor use only ˇ Pollution degree 2 Dimensions 142(L) × 28(W) × 27(D)mm Weight (battery included) Approx. 45g    Power source    1.5V (AAA) × 2 Safety standard EN 61010-1 CAT III 600V EN 61326-1

Category: Terminal

Sockets nylon    4 m/m sockets with shrouded    contact compatible with shrouded .    plugs and leads supplied with nuts    for panel mounting.     TER-6200B Black     TER-6200R Red    TER-6200G Green

FEATURES ● Designed for testing AC current and AC voltage.  ● 5 ranges for AC current testing.● The best resolution of leakage current measurement is 0.1mA.● Frequency selection : 50/60 Hz and Wide.● Data hold function.● Maximum reading.● Low battery indication.     SPECIFICATIONS       AC Current     Ranges Accuracy 50/60Hz WIDE 200mA(0~199.9mA) ±(1.5%rdg+2dgt) 40/1000Hz : ±(3.0%rdg+2dgt) 2A (0~1.999A) 20A(0~19.99A) 200A(0~199.9A) ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 0-500A ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 501-1000A ±5.5%rdg 40/1000Hz : ±10%rdg AC Voltage      Ranges AC 200V/AC600V Resolution 0.1V / 1V Accuracy ±(1.5%rdg+3dgt) GENERAL   Conductor size 55mm Max. Operating principle Dual slope integration Display 3½ digit (2000 counts) Low battery indication “ “ sign appears on the display when the battery voltage drops below accurate operating   level ...

FEATURES ● Microprocessor-controlled.● 68 x 34mm large LCD display.● 3½ digital LCD (2000 counts) a LCD indicated instrument for    insulation(MΩ), continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● Auto ranging.● Auto power off function.● Auto data hold function.● Rel function (ohm only)● Continuity buzzer.● External AC voltage warning.● Automatic circuit discharge.● BS 16th edition.     SPECIFICATIONS   Insulation Resistance     Test voltage 250V / 500V / 1000V Measuring ranges (Auto ranging) 0-20.00MΩ 0-200.0MΩ 0-2000MΩ Output voltage open circuit Rated test voltage +10% Accuracy 20MΩ : ±(1.5%rdg+2dgt) 200MΩ : ±(2.5%rdg+2dgt) 2000MΩ : ±(5%rdg+3dgt) Resolution 0-20.00MΩ : 10kΩ 0-200.0MΩ : 100kΩ 0-2000MΩ : 1MΩ Output current 1mA DC AC Voltage     Range 0-500V Resolution 1V Accuracy ±(1.5%rdg+3dgt) Continuity     Ranges 20Ω / 200Ω / 2000Ω Resolution 0-20Ω : 0.01Ω...

● 8 voltage settings: 240Vac, 2kV, 6kV, 11kV, 22kV, 33kV, 132kV, and 275kV.● High bright LED visual indication.● Sound indication.● Easy-to-prove method.● Self-test selection.● Use 3 × 1.5V “C” batteries.● High impact nylon casing.● Non-contact work by proximity.● Compatible with most link sticks.● Lightweight, robust, & compact.● Suitable for indoor and outdoor use.● Detects low voltage on any systems.● Easy access to batteries.● No special parts needed.● Meets EN 61326-1  EN 55011  EN 61000-4-2  EN 61000-4-3● United States Design Patent : US D474, 705 S● Special ranges are available upon request.

Category: Bench Type

Precision meters for plant maintenance, field servicing and    educational purposes. ● Taut Band movement with rectifier type. ● Multi terminals (4mm socket) for range selection. ● Carbon pointer, mirror scale to eliminate parallax error. ● High resistance to shock and vibration. ● Accuracy:±1.5% F.S. ● Scale length:80mm. ● Dimension:107(L) × 117(W) × 53(D)mm. ● Weight:Approx. 300g.

● Microprocesser-controlled. ● Measures earth resistance in three ranges : 40Ω, 400Ω, 4kΩ.● Capable of measuring earth voltage.● 3 ¾ digit (4000 counts).● LCD backlight display.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● Data hold function.● Relative function.● Auto power-off function.● Low battery indication.● Calibration performed with supplied test leads.     SPECIFICATIONS Measuring ranges Earth Resistance 0~40Ω / 0~400Ω / 0~4kΩ Earth Voltage 0~400V (40~500Hz) Accuracy Earth Resistance ±(2%rdg+3dgt) Earth Voltage ±(2%rdg+3dgt) Earth resistanceresolution 0~40Ω : 0.01Ω 0~400Ω : 0.1Ω 0~4kΩ : 1Ω Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx. Dimensions 163(L) x 102(W) x 50(D)mm Weight (battery included) Approx. 440g  Power source 1.5V (AA) x 6 Safety standards EN 61010-1 CAT IV 400V EN 61326-1 EN 61557-1 EN 61557-5