Category: Transmitters

The Highest accuracy up to ±1.0 % RH First humidity transmitter with Profibus-DP interface Self-monitoring and early warning guarantee high system availability Optimum adjustment concept thanks to adjustment of the entire signal chain incl. analog adjustment P2A software for parameterization, adjustment and analysis saves time and costs in commissioning and maintenance Calculation and presentation of all relevant humidity parameters

Category: Transmitters

The Highest accuracy up to ±1.0 % RH First humidity transmitter with Profibus-DP interface Self-monitoring and early warning guarantee high system availability Optimum adjustment concept thanks to adjustment of the entire signal chain incl. analog adjustment P2A software for parameterization, adjustment and analysis saves time and costs in commissioning and maintenance

Highly accurate humidity meas. to ±1%RH Internal data memory Convenient data analysis TopSafe for tough applications Channel 1: Temperature probe Type K/J/S, NTC Channel 2: Combi-probe humidity/temperature or temperature probe Pt100

Category: Anemometers

Measuring range: 0 to 150 m/sec Robust, thermal silicon chip sensor Penetration probe design, versatile use for pipe diameters from DN 50 (2") to DN 300 (12") Includes 5-point calibration certificate Measuring range: -50 to 400 ° C Minimum flow required: 2 m/sec Accuracy: +/-3 percent of reading, /-0.4 percent of final value Temperature dependency: compensated at 25 ° C, deviating temperatures: 0.1 percent of reading/kelvin Response time: t90 approximately 5 seconds Voltage supply: 12 to 24 Vdc +/-10 percent , power consumption less than 100 mA (starting current briefly 500 mA)

Category: Anemometers

Measuring range: 0 to 80 Nm/sec Robust, thermal silicon chip sensor Penetration probe design, versatile use for pipe diameters from DN 50 (2") to DN 300 (12") Includes 5-point calibration certificate Minimum flow required: 1 m/sec Ambient temperature: -10 to +60° C Accuracy: +/-3 percent of reading, /-0.4 percent of final value Temperature dependency: compensated at 25 ° C, deviating temperatures: 0.1 percent of reading/kelvin Response time: t90 approximately 5 seconds Voltage supply: 12 to 24 Vdc +/-10 percent , power consumption less than 100 mA (starting current briefly 500 mA)

Category: Transmitters

Leakage detection, compressed air consumption meaurement Consumption cost allocation Peakload management Measuring range: 2.3 to 700 Nm³/h Pipe diameter: DN 50 (for 2" pipes) Weight: 3.8 kg Max. display value norm volume flow: 840 Nm³/h Min./max. monitoring Control of consumption-dependent maintenance strategies Automatic, exact compressed air dosage

Category: Transmitters

Leakage detection, compressed air consumption meaurement Consumption cost allocation Peakload management Measuring range: 1.3 to 410 Nm³/h Pipe diameter: DN 40 (for 1 1/2" pipes) Weight: 3.0 kg Max. display value norm volume flow: 492 Nm³/h Min./max. monitoring Control of consumption-dependent maintenance strategies Automatic, exact compressed air dosage

Category: Transmitters

Leakage detection, compressed air consumption meaurement Consumption cost allocation Peakload management Measuring range: 0.75 to 225 Nm³/h Pipe diameter: DN 25 (for 1" pipes) Weight: 1.1 kg Max. display value norm volume flow: 270 Nm³/h Min./max. monitoring Control of consumption-dependent maintenance strategies Automatic, exact compressed air dosage