By Brands
Bante 903P portable multi-parameter meter used for measuring the pH, ORP and Dissolved Oxygen in water. General Features: Automatic Temperature Compensation (ATC) ensures highly accurate measurements over the entire range. Calibration due reminder prompts you to calibrate the meter regularly. Automatic endpoint function freezes the stable measured values for easy reading and recording data. Manual temperature calibration provides accurate temperature value. Help message as a operational guide to helps you understand how to use meter. Setup menu lets user customizes buffer standards, calibration points, stability conditions, resolution, temperature units, date and time to meet measurement requirements. Reset function can resumes all settings to factory default values. Expanded memory stores and recalls up to 500 readings. Built-in real-time clock stamps stored data to meets GLP standards. Stored data can be transferred into computer via USB communication interface.
Bante 904P portable multi-parameter meter used for measuring the Conductivity, TDS, Salinity, Resistivity and DO in water. General Features: Automatic Temperature Compensation (ATC) ensures highly accurate measurements over the entire range. Calibration due reminder prompts you to calibrate the meter regularly. Automatic endpoint function freezes the stable measured values for easy reading and recording data. Manual temperature calibration provides accurate temperature value. Help message as a operational guide to helps you understand how to use meter. Setup menu lets user customizes calibration points, stability condition, resolution, temperature units, date and time to meet measurement requirements. Reset function can resumes all settings to factory default values. Expanded memory stores and recalls up to 500 readings. Built-in real-time clock stamps stored data to meets GLP standards. Stored data can be transferred into computer via USB communication interface.
Bante 901 multi-parameter meter used for measuring the pH, Conductivity and TDS of liquids. General Features: Automatic Temperature Compensation (ATC) ensures highly accurate measurements over the entire range. Calibration due reminder prompts you to calibrate the meter regularly. Automatic endpoint function freezes the stable measured values for easy reading and recording data. Manual temperature calibration provides accurate temperature value. Help message as a operational guide to helps you understand how to use meter. Setup menu lets user customizes buffer standards, calibration points, stability conditions, resolution, temperature units, date and time to meet measurement requirements. Reset function can resumes all settings to factory default values. Expanded memory stores and recalls up to 500 readings. Built-in real-time clock stamps stored data to meets GLP standards. Stored data can be transferred into computer via USB communication interface.
Bante 902 multi-parameter meter used for measuring the pH, ORP, Conductivity, TDS, Salinity and Resistivity of liquids. General Features: Automatic Temperature Compensation (ATC) ensures highly accurate measurements over the entire range. Calibration due reminder prompts you to calibrate the meter regularly. Automatic endpoint function freezes the stable measured values for easy reading and recording data. Manual temperature calibration provides accurate temperature value. Help message as a operational guide to helps you understand how to use meter. Setup menu lets user customizes buffer standards, calibration points, stability conditions, resolution, temperature units, date and time to meet measurement requirements. Reset function can resumes all settings to factory default values. Expanded memory stores and recalls up to 500 readings. Built-in real-time clock stamps stored data to meets GLP standards. Stored data can be transferred into computer via USB communication interface.
Bante 903 multi-parameter meter used for measuring the pH, ORP and Dissolved Oxygen in water. General Features: Automatic Temperature Compensation (ATC) ensures highly accurate measurements over the entire range. Calibration due reminder prompts you to calibrate the meter regularly. Automatic endpoint function freezes the stable measured values for easy reading and recording data. Manual temperature calibration provides accurate temperature value. Help message as a operational guide to helps you understand how to use meter. Setup menu lets user customizes buffer standards, calibration points, stability conditions, resolution, temperature units, date and time to meet measurement requirements. Reset function can resumes all settings to factory default values. Expanded memory stores and recalls up to 500 readings. Built-in real-time clock stamps stored data to meets GLP standards. Stored data can be transferred into computer via USB communication interface.
Bante 904 multi-parameter meter used for measuring the Salinity Conductivity, TDS, Resistivity and Dissolved Oxygen in water. General Features: Automatic Temperature Compensation (ATC) ensures highly accurate measurements over the entire range. Calibration due reminder prompts you to calibrate the meter regularly. Automatic endpoint function freezes the stable measured values for easy reading and recording data. Manual temperature calibration provides accurate temperature value. Help message as a operational guide to helps you understand how to use meter. Setup menu lets user customizes calibration points, stability condition, resolution, temperature units, date and time to meet measurement requirements. Reset function can resumes all settings to factory default values. Expanded memory stores and recalls up to 500 readings. Built-in real-time clock stamps stored data to meets GLP standards. Stored data can be transferred into computer via USB communication interface.
ORPscan10 pocket ORP tester is used to monitors chemical reactions, quantify ion activity, or determine the oxidizing or reducing properties of samples. The meter is widely used in pharmaceutical research, aquaculture and food processing industry, etc. Features: Absolute or Relative mV measurements provides accurate readings. Single point offset calibration allows you adjust displayed value to a known standard. Hold function freezes current displayed value for easy viewing and recording. Auto-power off feature helps you effectively conserve battery life. Setup menu lets user customizes automatic or manual hold function, auto-power off feature to meet your personal preferences. Reset feature allows user to resume all of the default settings. Replaceable electrode reduces maintenance and replacement costs. Waterproof feature to ensures complete protection in harsh environments.
ORPscan20 pocket ORP tester is used to monitors chemical reactions, quantify ion activity, or determine the oxidizing or reducing properties of samples. The meter has a BNC plug which can connect any standard ORP electrode. Features: Absolute or Relative mV measurements provides accurate readings. Single point offset calibration allows you adjust displayed value to a known standard. Hold function freezes current displayed value for easy viewing and recording. Auto-power off feature helps you effectively conserve battery life. Setup menu lets user customizes automatic or manual hold function, auto-power off feature to meet your personal preferences. Reset feature allows user to resume all of the default settings. Replaceable electrode reduces maintenance and replacement costs. Waterproof feature to ensures complete protection in harsh environments.