Process Analyzers

  • Filter

Resistivity Analyzer for Ultra-Pure Water AQM-100A Compact DIN 96 size Best suited for water quality control in ultra-pure water production lines  Two detectors connectable Meas. range 0.00 - 20.00 MΩ・cm

Panel Type Resistivity Analyzer AQM-210A Compact DIN 96 size Best suited for water quality control in ultra-pure water production lines  Two detectors connectable RS-232 equipped as standard specification Output: 2-channel, insulated, 4 - 20mA Meas. range 0.00 - 20.00 MΩ・cm

Electromagnetic Conductivity Transmitter MDM-135A (2-wire) Electromagnetic conductivity analyzer for field installation in a compact and rigid aluminum enclosure  Made for accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali) Alterable output range Meas. range Minimum : 0 - 2 mS/cm Maximum : 0 - 2000 mS/cm

Electromagnetic Concentration Transmitter MDM-137A (2-wire) Electromagnetic concentration analyzer for field installation in a compact and rigid aluminum enclosure   Conductivity of NaCl, HCl, H2SO4, etc. are measured and converted to concentration (%)data automatically Assignable measurement range Examples of measurement ranges NaCl: 0 - 10% HCl: 30 - 40% H2SO4: 93 - 99.5% NaOH: 0 - 15%

Electromagnetic Conductivity Transmitter MBM-160(4-wire) Electromagnetic conductivity analyzer for field installation in a compact aluminum diecast  enclosure Made for accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali) 2-point contact signal, 2-channel output including temperature (RS-232 optional) Power source: 90 - 264VAC, 50/60Hz Meas. range Minimum: 0 - 2 mS/cm Maximum: 0 - 2000 mS/cm

Electromagnetic Concentration Transmitter MBM-162 (4-wire) Electromagnetic concentration analyzer for field installation in a compact aluminum diecast enclosure Conductivity of NaCl, HCl, H2SO4, etc. are measured and converted to concentration (%) data automatically 2-point contact signal, 2-channel output including temperature (RS-232 optional)  Examples of measurement ranges NaCl: 0~10% HCl: 30~40% H2SO4: 93~99.5% NaOH: 0~15%

Panel Type Electromagnetic Conductivity Analyzer MBM-100A Compact DIN 96 size Accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali) 2-point contact signal, 4 - 20mA output (RS-232 optional)    Meas. range Minimum : 0 - 2 mS/cm Maximum: 0 - 2000 mS/cm

Panel Type Electromagnetic Concentration Analyzer MBM-102A Compact DIN 96 size Conductivity of NaCl, HCl, H2SO4, etc. are measured and converted to concentration (%) data automatically Assignable measurement range 2-point contact signal, 4 - 20mA output (RS-232 optional) Examples of measurement ranges NaCl: 0 - 10% HCl: 30 - 40% H2SO4: 93 - 99.5% NaOH: 0 - 15%