SEW-Taiwan

Insulation Testers

  • Filter

FEATURES ● Measures insulation (MΩ), Continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338” ) large LCD display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 210mA short circuit testing current for continuity.● External voltage warning indication.● Fuse protection.● BS 16 edition     SPECIFICATIONS   Insulation Resistance     Test voltage (DC V) 250V / 500V 1000V Measuring ranges 0-200MΩ  0-2000MΩ Resolution 1 count / 100kΩ 1 count / 1MΩ Accuracy ±(1.5%rdg+5dgt) ±(3%rdg+3dgt) (under 1GΩ/2000MΩ) ±(5%rdg+3dgt) (under 2GΩ/2000MΩ) Output voltage on open circuit Rated test Voltage +10% Output current 1mA DC Power consumption 250mA  Continuity     Measuring range 0-20Ω    0-2kΩ Accuracy ±(1.5%rdg+5dgt) ±(1.5%rdg+3dgt) Resolution 0.01Ω      1Ω Buzzer sound...

FEATURES ● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● Fully protected: crow bar.● Carry case.● EEPROM calibration.     SPECIFICATIONS             Test voltage (DC V) 0.5kV /   1kV   /   2.5kV   /   5kV Measuring ranges (Auto-Ranges) 0-25GΩ / 0-50GΩ / 0-125GΩ / 0-250GΩ Accuracy ±3% rdg Output power limit 50uA to 100uA (1W) Live warning > 500V AC Operation temperature 0°C to 40°C Operation-humidity 85% Max. relative humidity Dimensions 330(L) × 260(W) × 160(D)mm Weight (battery included) Approx. 3500g Power source 1.5V “C”× 8 Alkaline batteries Safety standard EN 61010-1 EN 61326-1

FEATURES ● High quality Taut Band movement.● Measures insulation(MΩ), continuity(Ω) and AC voltage.● Instant operation is possible with a push button, convenient timer is    provided with automatic power off after three to five minutes to save    the battery power.● LED (red) indication when testing insulation and continuity.● Use of a high efficiency and accurate DC-DC converter.● Most suitable for insulation resistance measurement of electrical    household appliances, power line distribution and installation.     SPECIFICATIONS      Insulation Resistance     Test voltage (DC V) 250V     /     500V       /     1000V Output voltage on open circuit Rated test voltage +10% Measuring ranges (Mid-scale value) 0-100MΩ /   0-200MΩ     /     0-400MΩ   (1MΩ)   /   (2MΩ)       /      ...

FEATURES ● Timer for test function (count 3-5 minutes).● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338”) large LCD display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 200mA short circuit testing current for continuity.● External voltage warning indication.● Fuse protection.● Data hold function● Auto power off function.● BS 16 edition.     SPECIFICATIONS   Insulation Resistance     Test voltage (DC V) 250V / 500V / 1000V Measuring ranges (Auto ranging) 0-20MΩ / 0-200MΩ / 0-2000MΩ Accuracy 0-20MΩ : ±(1.5%rdg+5dgt) 0-200MΩ : ±(2.5%rdg+3dgt) 0-2000MΩ : ±(5%rdg+5dgt) Output voltage on open circuit Rated test Voltage +10% Output current 1mA DC Power consumption 250mA  Continuity     Measuring range 0-20Ω / 0-200Ω / 0-2000Ω Accuracy ±(1.5%rdg+3dgt) Resolution 0.01Ω / 0.1Ω / 1Ω Buzzer sound below under 10Ω Open circuit terminal voltage 4V DC...

FEATURES ● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● Fully protected: crow bar.● Carry case.● EEPROM calibration.     SPECIFICATIONS             Test voltage (DC V) 1kV   /   2.5kV   /     5kV   /     10kV Measuring ranges (Auto-Ranges) 0-50GΩ / 0-125GΩ / 0-250GΩ / 0-500GΩ Accuracy ±3% rdg Output power limit 50uA to 100uA (1W) Live warning > 500V AC Operation temperature 0°C to 40°C Operation-humidity 85% Max. relative humidity Dimensions 330(L) × 260(W) × 160(D)mm Weight (battery included) Approx. 3600g Power source 1.5V “C”× 8 Alkaline batteries Safety standard EN 61010-1 EN 61326-1

FEATURES ● High quality Taut Band movement.● Measures insulation(MΩ) and AC voltage.● LED indiction for testing insulation.● Highly efficiency and accurate DC-DC converter.● Battery check function.● Compact and lightweight.● AC voltage measurement can be made without depressing the test button.     SPECIFICATIONS         Insulation Resistance     Test voltage (DC V) 1000V Output voltage on open circuit Rated test voltage +10% Measuring ranges 0-2000MΩ Mid-scale value 50MΩ Accuracy 2-1000MΩ : ± 5% rdg 0.7% of scale length at other ranges Short circuit current 1mA AC Voltage     Range 0-500V Accuracy ± 2.5% of full scale General     Operating temperature & humidity 0°C ~ 40°C relative humidity up to 85% Storage temperature & humidity -10°C ~ 50°C relative humidity up to 85% Dimensions 175(L) × 85(W) × 75(D) mm Weight (battery included) Approx. 560g Power source 1.5V (AA) × 8 Safety...

FEATURES ● Microprocessor-controlled.● 68 × 34mm(2.677” × 1.338”) large LCD display.● 3½ digital LCD(2000 counts) a LCD indicated instrument for    insulation.(MΩ), continuity(Ω) and AC voltage.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA DC load.● >200mA short circuit testing current for a resistance tests.● Auto ranging.● REL function.● Auto power OFF.● Fuse protection.● Auto data hold.● BS 16 edition.     SPECIFICATIONS   Insulation Resistance     Test voltage (DC V) 250V / 500V / 1000V Measuring ranges (Auto ranging) 0-2MΩ / 0-20MΩ / 0-200MΩ / 0-2000MΩ Output voltage on open circuit +10% Accuracy 0-2MΩ : ±(5%rdg+5dgt) 0-20MΩ : ±(1.5%rdg+5dgt) 0-200MΩ : ±(2.5%rdg+3dgt) 0-2000MΩ : ±(5%rdg+5dgt) Resolution 0-2MΩ : 1kΩ 0-20MΩ : 10kΩ 0-200MΩ : 100kΩ 0-2000MΩ : 1MΩ Output current 1mA DC AC Voltage     Range 0-600V Resolution 1V Line frequency...

FEATURES ● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV,    3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV,    9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bargraph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present(>500Vac or    Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.     SPECIFICATIONS             Test voltage (DC V) 0.5kV to 10kV (0.5kV increment steps) Insulation resistance (Auto ranging) 25GΩ / 0.5kV 25GΩ at 0.5kV → 500GΩ at 10kV Accuracy  ± 3% rdg ± 1 dgt Output power limit 50uA to 100uA (1W) Live warning > 500V AC ...