FEATURES ● Microprocessor-controlled.● Four terminal measurement.● Measures down to 100μΩ.● 5 Ranges from 200.0mΩ to 2000Ω.● Maximum resolution of 100μΩ.● Three test currents with over-temperature protection.● Protection against inadvertent connection to over voltage.● Large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave inside.● EnerSave Auto hold.● EnerSave Auto off.● Lightweight, robust & compact.● Indicators show if reading may be invalid (RP, RC, and     temperature).● "O-Ring” sealed case.     SPECIFICATIONS         Measuring ranges 0-200.0mΩ in steps of 100μΩ 0-2000mΩ in steps of 1mΩ 0-20.00Ω in steps of 10mΩ 0-200.0Ω in steps of 100mΩ 0-2000Ω in steps of 1Ω Accuracy ±0.5% of reading ±2 digits over the operating temperature range, -15ºC to +55ºC, with the supplied test leads Test current 1mA=>2000Ω range 10mA=>200 / 20Ω ranges 100mA=>2000m / 200mΩ ranges Test current accuracy ±0.1% Protection fuses Mains = 0.5A,...

FEATURES ● True measurement of speaker systems actual impedance at 1kHz.● Three test ranges (20Ω / 200Ω / 2000Ω) allow testing of home    theater and commercial sound systems.● Measures transformer impedances.● Battery operated.● Low battery indication.● Data hold function.● Timer function for continuous hands free operation.● The timer can last about 3-5 minutes when users press.● TEST ON/OFF button.     SPECIFICATIONS       Measuring ranges 0-20Ω / 0-200Ω / 0-2000Ω Test frequency 1kHz Accuracy 20Ω : ± 2%rdg±2dgt or ± 0.1Ω, which is greater 200Ω / 2000Ω : ± 2%rdg±2dgt Low battery indiction “  “ Symbol appears on the display Data hold indiction “  “ Symbol appears on the display Display LCD 3½ digit (2000 counts) Dimensions 205(L) × 90(W) × 55(D)mm Weight (battery included) Approx. 530g Power source 1.5V (AA) × 6 Safety standard EN 61010-1 CAT III 300V EN 61326-1

Category: Light Meter

FEATURES ● Wide range for measurements up 40000 lux and 4000 fc.● 0.01 lux and 0.001 fc resolution for accurate low light level   measurements.● Light sensor cover is included for preserving sensor life.● Auto off function.● Data hold and peak hold function.● Low battery indication.● Over range indication.● Auto-ranged.● Manual-ranged.● Calibration mode is provided.● 9V battery system.● Selection key for lux and fc.● The spectral sensitivity close to CIE photopic curve.● Ideal tool for workplace, clean-room and computer room light   testing.● Video, photographic, office, classroom, and architectural uses.     SPECIFICATIONS         Measuring ranges 39.99 / 399.9 / 3999 / 39990 lux 3.999 / 39.99 / 399.9 / 3999fc Resolution 0.01 lux - 10 lux 0.001 fc - 1 fc Accuracy ±(3%rdg+5dgt) Calibrated to standard incandescent lamp, 2856°K. Display 4000 count LCD Photo sensor Silicon photodiode Operating / storage conditions 0°C - 40°C < 80 % R.H. -10°C - 50°C < 80 % R.H. Dimensions 194(L) x...

FEATURES ● Max. & Min. function.● Over & under range indication.● 4-digit LCD with bar graph.● Frequency weighting characteristic for 2 times per second.● AC signal output.● Low battery indication.     SPECIFICATIONS         Measuring ranges Lo :   30dB~80dB Med : 50dB~100dB Hi :   80dB~130dB Accuracy ± 1.5dB(at Reference Range) Reference sound level & frequency 94dB, 1kHz Resolution 0.1dB Detector-indicator characteristic Fast : 125ms Slow : 1s Analogue signal output AC 1Vrms for each range Dimensions 235(L) x 58.4(W) x 34(D)mm Weight (battery included) Approx. 220g Power source 9V(6F22) × 1 Safety standard   IEC 651 Type 2 &   ANIS S1.4 Type 2  EN 61326-1

FEATURES ● High quality Taut Band movement.● Four functions : DC current, AC current, AC+DC current, and ACV   measurement.● Three input resistance ranges: 1kΩ,1.5kΩ and 2kΩ.● 200uA full scale value.● ±2.5% full scale value accuracy.● Built-in overload protection circuit.● Robust, compact and easy to carry.     SPECIFICATIONS            Ranges    DC Current : 0.1-1-10mA AC Current : 0.1-1-10mA AC+DC current : 0.1-1-10mA AC Voltage : 150-300V (50/60Hz) Accuracy : ±2.5% of full scale Input impedance Current Ranges : 1kΩ, 1.5kΩ and 2kΩ Voltage Ranges : 150V/500kΩ 300V/1MΩ Working frequency 20Hz ~5kHz Overload protection Withstands 30mA AC for 10 minutes for each current measuring range Operating temperature 0ºC ~ 40ºC Operating humidity Max. 80% R.H. Dimensions 210(L) × 210(W) × 100(D)mm Weight (battery included) Approx. 1395g Power source 1.5V (AA) × 8 Safety standard EN 61010-1 CAT III 600V EN 61326-1

FEATURES ● 191 CBI is an easy tool to find the circuit breaker or fuse supplying    electrical power to an outlet or lighting fixture. Just plug the    transmitter into the outlet.● Use the receiver to scan the circuit breaker panel box. An audible    tone will be clearly heard when the right circuit breaker is scanned.● The plug of transmitter is changeable. The plug of transmitter could    be changed for customers' requirement from different countries.     SPECIFICATIONS       Operation voltage 220~240 VAC Operation frequency 50 / 60 Hz Transmitter power Powered by wall outlet Receiver power 9V(6F22) × 1 Safety standard EN 61010-1 EN 61326-1

FEATURES ● 190 CBI is an easy tool to find the circuit breaker or fuse supplying    electrical power to an outlet or lighting fixture. Just plug the    transmitter into the outlet.● Use the receiver to scan the circuit breaker panel box. An audible    tone will be clearly heard when the right circuit breaker is scanned.● The plug of transmitter is changeable. The plug of transmitter could    be changed for customers' requirement from different countries.     SPECIFICATIONS       Operation voltage 110~120 VAC Operation frequency 50 / 60 Hz Transmitter power Powered by wall outlet Receiver power 9V(6F22) × 1 Safety standard EN 61010-1 EN 61326-1

FEATURES ● The 188FFF is a Fuse and Fault Finder which comprises of two    parts : The Receiver and the Transmitter.● The Transmitter, draws a current from the mains supply circuit to   which it is connected to. The Signal● Current from the Tx is at about 10kHz. The Transmitter is powered   by the mains and requires no batteries.● The 10kHz signal current generated by the Transmitter is then   searched(sniffed) by the Receiver to detect the Fuse, Circuit   Breaker or the faulty circuit.● The Receiver is a tuned circuit which has it's center frequency tuned    to about 10kHz. The sensor is located in the tip of the Receiver.● The amplitude of the received signal is shown on a bar-graph type    Leds.● The more Leds ON, the stronger the signal.● The Receiver uses one 9V battery.     SPECIFICATIONS Receiver     Tuner circuit mid frequency 10kHz Bar graph leds 9 Battery indicator led 1 On button 1 Off button 1 Buzzer 1 Auto-off(Min) approx 1 ...