SEW-Taiwan

SEW New

  • Filter

FEATURES ● Microprocessor-controlled.● Measures Insulation Resistance, voltage (AC-DC) measurements   with automatic hold facility, diode, ohm, and continuity with a short   circuit current of minimum 220mA.● Auto-off function.● Energy conservation feature.● Ener-Save™ limit the test duration to about 10 Seconds.● Quick Test and EnerSave™ are unique features. Both saves energy.● No moving parts. All calibration are saved internally in a non volatile memory.● Easy calibration at any facility around the world.● Operates with rechargeable batteries, alkaline or low cost general purpose batteries.● Low cost maintenance, calibration, and ownership.● Complies to all the latest regulations, including UK.     SPECIFICATIONS       Insulation Test     Test voltage (DC V) and Measuring ranges 250V / 0.2M~2GΩ 500V / 0.2M-4GΩ 1000V / 0.2M-8GΩ Output voltage @ 1mA Rated test Voltage +10% Max Accuracy 0.2M~4GΩ : ±3%rdg   4GΩ~8GΩ : ±5%rdg When voltage is constant, Current is limited at ...

Category: Test Leads

Wire : PVC UL 1803 / 18AWG.    length : 1100±30mm    Out diameter : 4.0mm    Temperature tolerance range : -40ºC~105ºC    Braid copper wires : 170 / 0.08mm● Terminal :    105º angle 4mm brass banana plug (nickel plated) with caged and    insulated sheathing to avoid the brass oxidation.● Rating :    EN 61010-031:2002 + A1:2008    CAT III 1000V 10A / CAT IV 600V 10A

FEATURES ● Indicates phase rotation.        ● Indicates phase presence.● No battery required.● Phase rotation phase presence indicated on large    liquid crystal display.● Small, rugged enclosure.● Color coded test leads.● Phase presence indication from as low as 40Vac to   as high as 500Vac.● Fused.● Lightweight, robust and compact.● EN 61010-1 CAT III 500V   EN 61010-2-032     SPECIFICATIONS       ELECTRICAL     Determination of the Phase Presence Nominal Voltage for Phase Presence Indication (the voltage required for the LCD L1, L2, L3 indicators to come on) From 40Vac to 500Vac. Frequency range From 15Hz to 400Hz. Determination of the Phases Rotary Field Direction:   Direction Indication by LCD Display(the voltage required to have the LCD Direction Arrows to indicates and the L1 L2 L3 or L3 L2 L1 indicators to show) From 40 to 500Vac. Frequency range From 15 Hz to 400Hz Protection     Over load 700V(between...

FEATURES ● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on low ohms : 3Ω & 500Ω.● Compact and lightweight.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● BS 16 edition.     SPECIFICATIONS         Insulation Resistance     Test voltage (DC V) 250V     /   500V   /   1000V Output voltage on open circuit Rated test voltage +10% Measuring ranges 0-100MΩ / 0-200MΩ / 0-400MΩ Mid-scale value 1MΩ     /  ...

FEATURES ● 4000 - count LCD.● Full automatic measurement.      ◎ Voltage measurement.      ◎ Current measurement.      ◎ Resistor measurement.      ◎ Capacitor measurement      ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded    banana plugs and recessed input terminals.     SPECIFICATIONS         AC A 400.0/2000A (40~500Hz) 0~1500A           ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt) AC V 400.0mV ±(2.0%rdg+3dgt) 4.000/40.00/400.0/750V ±(1.5%rdg+3dgt)     40~500Hz DC A 400.0/2000A 0~1500A           ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt) DC V 400.0mV/4.000/40.00/400.0/1000V...

FEATURES ● Microprocessor-controlled.● Telecommunication test voltage : 50V and 100V.● Large range of insulation test voltages: 50, 100, 125, 250, 500, 1000V.● Mov / protection devices test.● Gas Arrester function.● Automatic voltmeter AC/DC at Start/Reset.● Test ON-OFF.● Battery test.● Safety voltmeter before each test.● Auto-discharge on all test and all ranges.● Battery test at Switch ON-TEST.● Smart hold & Stop on voltmeter AC/DC.● eads AUTO-NULL Key.● Test Auto-stop.● Auto range.● Ener-Save™.     SPECIFICATIONS   Insulation Resistance     Test voltage (DC) and Measuring ranges 50V / 0.1MΩ~400MΩ 100V / 0.1MΩ~800MΩ 125V / 0.1MΩ~1GΩ 250V / 0.2M~2GΩ 500V / 0.2MΩ~4GΩ 1000V / 0.2M~8GΩ Output voltage @ 1mA Rated test Voltage +10% Accuracy 0.1MΩ~4GΩ : ±3%rdg 4MΩ~8GΩ : ±5%rdg Nominal voltage rated 1mA Short circuit current 1.2mA Polarization index(PI) ˇ Detective absorption ratio (DAR) ˇ Continuity     Ranges 0.01~100Ω / 100 ~300Ω / 300~1999Ω ...

Category: Test Leads

The spring-shrouded 4mm brass caged banana probe tip.● Double insulated silicone wire 1m.● Safety straight input plug.● Rating : EN 61010-31:2002 + A1:2008                  CAT III 1000V 10A    AL-30R Red, AL-30B Black, AL-30G Green● AL-30F It is the fused version for AL-30.    Fuse size : 6x32mm    Rating : EN 61010-031:2002 + A1:2008                  CAT III 250V 10A / 500V 10A / 690V 2A    AL-30FR Red, AL-30FB Black