Current Clamp DMM Accys

  • Filter

Operates with the Fluke 1750 Power Recorder It supplies accurate nonintrusive measurement of ac current The probe has a current range from 0.05 A to 40 A The frequency range is 40 Hz to 5 kHz The clamp is approved for CAT III 600 V

Measures AC current from 100mA to 800 A rms 30 Hz to 10 kHz frequency range CAT III 600 V rating Accepts up to 54 mm (2.1 in) diameter conductor size 1000:1 conversion factor for easy calculation Rugged positive action design

The i6000sflex is an AC current probe utilizing the Rogowski principle It can be used to measure currents up to 6000A when used in conjunction with oscilloscopes, recorders or data loggers The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas Current Ranges: 60A/600A/6000A AC RMS Output Sensitivity (AC coupled): 50 mV /5mV / 0.5mV per A Frequency Range: 10 Hz to 50 kHz (- 3 dB) Load Impedance: 100 kOhm minimum Accuracy (at +25°C): ±1% of range (45–65 Hz) Linearity (10% to 100% of range): ±0.2% of reading

The i6000sflex is an AC current probe utilizing the Rogowski principle It can be used to measure currents up to 6000A when used in conjunction with oscilloscopes, recorders or data loggers The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas Current Ranges: 60A/600A/6000A AC RMS Output Sensitivity (AC coupled): 50 mV /5mV / 0.5mV per A Frequency Range: 10 Hz to 50 kHz (- 3 dB) Load Impedance: 100 kOhm minimum Accuracy (at +25°C): ±1% of range (45–65 Hz) Linearity (10% to 100% of range): ±0.2% of reading

Low level current clamp measures up to 5 A ac Compact shape makes transporting and storing convenient; the clamp measures only 116 x 43 x 23 mm (4. 6 x 1.7 x .9 inches) Take accurate readings without breakings the circuit CAT III 600 V (For insulated conductors only)

Expand the use of your Fluke 430 series power quality tool with this 5A ac current clamp Specially configured to provide low current accuracy while taking measurements on secondary current transformers Low level current clamp measures up to 5A ac Compact shape makes transporting and storing convenient; the clamp measures only 116 x 43 x 23 mm (4. 6 x 1.7 x .9 inches) Take accurate readings without breakings the circuit CAT III 600 V (For insulated conductors only)

Current Range: 6000 A AC Frequency Range: 10 Hz to 7 kHz (-3 dB) Accuracy: +/- 1% of reading (@25 C, 50 Hz) i430-Flexi-TF works with: Fluke 434-II Series II Three-Phase Energy Analyzer Fluke 435-II Series II Three-Phase Power Quality and Energy Analyzer Fluke 437-II Series II 400 Hz Three-Phase Power Quality and Energy Analyzer

Current Range: 6000 A AC Frequency Range: 10 Hz to 7 kHz (-3 dB) Accuracy: +/- 1% of reading (@25 C, 50 Hz) i430-Flexi-TF works with: Fluke 434-II Series II Three-Phase Energy Analyzer Fluke 435-II Series II Three-Phase Power Quality and Energy Analyzer Fluke 437-II Series II 400 Hz Three-Phase Power Quality and Energy Analyzer