YOKOGAWA MIXED SIGNAL OSCILLOSCOPES DLM4000

The DLM4000 is a unique to the industry eight-channel mixed-signal oscilloscope suitable to test and debugging applications in the embedded systems, power electronics, mechatronics, and automotive sectors. Available in both 350 MHz and 500 MHz models, the 2.5 GSa/sec DLM4000 features eight analog input channels. The eighth input channel features Flex MSO which converts to a 8-bit logic analyzer at the push of a button; add sixteen additional logic analyzer inputs as an option, for 24-bit logic analysis. Advanced measurement and analysis features such as power analysis and serial-bus analysis, digital filtering, user-defined math, and super-long record lengths (up to 125 Mega Points) make the DLM4000 a super powerful engineering tool. High-resolution 12.1-inch LCD display, compact landscape format, ergonomic and friendly user-interface make it easy to use.

  • DETAILS
    • FEATURES:

      12.1 Inch LCD Enables Eight Waveforms to be Easily Observed

      Typical Demanding Applications for the Eight-Channel DLM4000

      Motor Control & Inverter Circuit Development


      Cipy Thi One Key to efficient and reliable high-performance electric motors is the modern inverter design, or ‘Intelligent Power Module’. Multi-channel, high-speed waveform measurement is an absolute necessity. Four channels are simply NOT enough. Boasting eight true analog inputs, the DLM4000 empowers today’s engineer with a convenient and comprehensive measurement system.

       

      Electronic Control Unit & Mechatronic Test
      Electronic Control Unit

      Numerous I/O analog, digital, and serial-bus waveforms surrounding the Electronic Control Unit (ECU) must be measured. The DLM4000 offers ample channel-count and architecture to monitor eight analog channels and up to 24-bits of logic input while simultaneously performing protocol analysis such as UART, I²C, SPI, CAN, LIN and FlexRay. The DLM4000 can speed up the R&D process.

      Power Supply & Power Coverter Test

      Power Supply And Power Converter

      During the evaluation of power supply design, it is necessary to measure noise, ripple, voltage margin and current, as well as timing margins and the jitter of the startup-shutdown sequences. As the number of waveforms in modern power supply designs is increasing, especially for intelligent digitally-controlled power supplies, battery management systems, and wireless power supply systems- a four channel oscilloscope is not enough.


      Troubleshooting, Total System Test
      Troubleshooting Total System Test

      For laboratory and field troubleshooting, the ability to measure as many suspicious signals as possible enables quick solutions to be found. The 8 channels of the DLM4000 provide the capability to measure more signals at one time, both now and to meet future needs.

      • FUNCTIONS

        Reliable Capture from Fast-Short Pulses to Long Recordings.

        For The Fast Short Waveform CopyFor the fast-short waveforms, the Comprehensive Trigger Suite captures the waveforms you need! In addition to basic trigger functions such as Edge, State, and Pulse Width, advanced trigger types are provided-including Edge OR between multiple channels, Serial Bus trigger in which a combination of two bus signals is possible, or an A and B combination of different trigger types

        Best in Class Deep Memory & Architecture

        Extra Deep Memory (125 Mega-Points) Enables Long-Duration Measurement 

        For four-channel measurements in single shot mode, you can add the /M2 Memory expansion option, which provides up to 125 Mpoints of memory. Even at a fast sampling rate of 1.25 GS/s, records as long as 100 milli-seconds can be captured. Yokogawa’s proprietary ScopeCORE IC assures responsiveness even for long record lengths. ScopeCORE maintains responsive waveform display even during parametric measurements and waveform calculations and defines the architecture and power of the DLM4000.
        In order to find and display the desired parts of the signal within the deep memory, powerful waveform search and a unique dual-window zoom function are provided.

                                       Extra Deep Memory                 

        Replay Waveforms So You Never Miss an Abnormal Waveform

        History Function

        With the DLM4000 Series, up to 20,000 previously captured waveforms can be saved in the automatically segmented acquisition memory without sacrificing acquisition speed. History Memory allows you to display one or all of the previously captured waveforms on screen. You can also perform cursor measurements, computation, and other operations on history waveforms.

                                            History Function

        History Search Function

        With the DLM4000 Series, you can search the 20,000 previously captured waveforms for history waveforms that meet specified search criteria. You can also perform cursor measurement and other types of analysis on the search results.

        Replay Function

        Waveforms can be displayed one at a time, using the rotary knob. With the Replay function, history waveforms can be automatically played back, paused, and fast-forwarded.

        • OPTIONS & ACCESSORIES

          Power Supply Analysis Function (/G4)

          Example of Switching Loss Analysis:

             Switching Los Analysi            

          The built-in algorithm fine tunes Power Loss calculations. User-specified parameters include devices such as IGBTs and MOSFETs.

          By dividing the long memory into segments, the Safe Operating Area can be analyzed and peak voltages between switching cycles can be compared using overlaying or one-by-one replay.

          Display a list of switching loss of each cycle and save the results.

          User-Defined Math (/G2)

          Example of the functions in the /G2 option:

          Duty cycle analysis for PWM waveform,F-V conversion, High-pass/Low-pass/Band-pass filtering, moving average, differential-integral, trigonometric, exponential-logarithm, arithmetic calculation of multiple channels, DA conversion of logic signals.

                       UDM Example              

          Expansion of FFT Calculation:

          In addition to power spectrum, advanced FFT functions, such as coherence and transfer function calculations are available to detail frequency-domain analysis.

                          UDM Expansion                           

          Serial Bus Analysis Function (/F1, /F2, /F3, /F4, /F5, /F6)

          Auto-Setup Saves Time!

          Hardware-Based Decoding

          Dual Bus Analysis

          Serial Bu Auto Setup Hardware Bnased Decoding Dual Bu Analysi

          Intelligent auto-setup enables quick and easy setup. The bit-rate and voltage thresholds are set automatically.

          Serial-Bus waveforms are processed in real-time by a dedicated processor. Decoded serial-bus data is displayed alongside the bus waveform in a user-selected format.

          Many systems contain multiple serial buses. The DLM4000 analyses up to four different serial-bus types simultaneously.

          Accessories

          Easy Probing for Floating Signals:
          High Voltage Differential Probe

          Wide Range of Current Measurement:
          Current Probe

          Enables Precise Power Measurement:
          Deskew Correctional Signal Source

          Easy Probing Wide Range Enable Precise
          The High Voltage Differential Probe range includes models such as the company PBDH0150 (1400/peak) as well as the 701926 (7 kVpeak).

          The PBC100 and PBC050 high-bandwidth current probes measure DC to 100MHz and 50MHz at up to 30Arms. The 701931 is available for higher currents up to 500Arms. The current probe range covers a wide range of applications.

          When measuring very fast switching devices, probe delay time correction (de-skew) is crucial. The 701936 signal source and auto de-skew feature makes de-skewing quick and simple.

          Analyzing High-Speed Differential Signals:
          PBDH1000 Differential Probe

          Probing Fast & Slow Logic Signals:
          PBL100 & PBL250 Logic Probe

          Analyzing High Probing Fast

          The PBDH1000 Differential Probe features high input-resistance, wide bandwidth, and a wide input-voltage range. The PBDH1000 is perfect for measuring the noise or surge voltage of in-vehicle high-speed serial bus waveforms, including CAN and FlexRay.

          In some cases, high input resistance is important. Yokogawa offers two types of logic probes-the PBL100 (100 MHz), which has minimal loading, and the PBL250, ideal for probing high-speed logic waveforms.

          • CONNECTIVITY

            Broad Connectivity and Easier Control

            Screen Shot 2012 10 11 At 2.17.19 PM 1

            Improve Efficiency by Using PC

            The DLM4000 is not Windows based, so it is safer when connecting to networks.

        • MODEL NUMBERS
          ModelDescription
          DLM4038 DLM4038 350 MHz Mixed Signal Oscilloscope 8-channel 8-bit
          DLM4058 DLM4058 500 MHz Mixed Signal Oscilloscope 8-channel 8 bit
          • ACCESSORIES

            Differential Probe 100 MHz/1400 V 700924

            Differential Probe 100 MHz/1400 V 700924

            Differential probe powered by Yokogawa Digital Oscilloscopes, ScopeCorders, external power supply or internal battery.

            Differential Probe 15 MHz/1000 V 700925

            Differential Probe 15 MHz/1000 V 700925

            Differential probe powered by internal battery.

            900 MHz FET probe 700939

            900 MHz FET probe 700939

            Active Probe, 10Vp, 900MHz, 10:1, 2.5MΩ / 1.8pF, 1.5m, FET Probe w/ LEMO power pig-tail

            Probe Stand 701919

            Probe Stand 701919

            Using a probe stand with a flexible arm and heavy base to hold and stabilize probes can simplify circuit board testing.

            500 MHz Differential Probe 701920

            500 MHz Differential Probe 701920

            Differential Probe, 12Vp Differential, 30Vp Common-Mode, 500MHz, 10:1, 100kΩ, w/ built-in power cable (LEMO lead)

            100 MHz Differential Probe 701921

            100 MHz Differential Probe 701921

            Bandwidth: DC to 100 MHz (-3 dB)

            200 MHz Differential Probe 701922

            200 MHz Differential Probe 701922

            The 701922 is a 10:1 Differential Probe rated at 20Vpeak differential voltage input and 60Vpeak Common-Mode input with 200MHz bandwidth (-3dB). This probe is recommended for CAN bus and can be used with virtuallly any oscillscope with an internal 50Ω termination or use the external 50Ω 700976. This probe is powered via a built in pig-tail LEMO lead. This probe can be powered with Yokogawa scope option /P2 or /P4, or an external power supply 700938-3-D or 701934-D. The probe is supplied with one each pinchers, B9852MF black and B9852MG red and a 50cm ground extension.

            1.0 GHz Differential Probe (PBDH1000) 701924

            1.0 GHz Differential Probe (PBDH1000) 701924

            The PBDH1000 (701924) is a 25Vp Differential Probe powered by the Yokogawa Probe Interface. This probe can be used only with the Yokogawa DLM2000, DL6000, DLM6000, DL9000, and SB5000 series oscilloscope. 

            Differential Probe 50 MHz/7000 V 701926

            Differential Probe 50 MHz/7000 V 701926

            High Voltage Differential probe powered by Yokogawa Digital Oscilloscopes, ScopeCorders, external power supply or internal battery.

            Differential Probe 150 MHz/1400 V 701927

            Differential Probe 150 MHz/1400 V 701927

            The 701927 is a 50:1 or 500:1 high voltage (1400V peak) probe with extended bandwidth covering DC to 150MHz, This probe provides a balanced differential input, to be used with oscilloscopes with single-ended inputs (1 MΩ Input Impedance).  This probe works with DLM2000, DLM4000, DL6000, DLM6000, DL9000 and SB5000. This probe is conveniently powered by the Yokogawa Probe Interface.

            Current Probe 100 MHz/30 ARMS 701928

            Current Probe 100 MHz/30 ARMS 701928

            Current probe front-end powered, recognized automatically and adjust zero position from the operation of the DLM2000, DLM4000, DL6000/DLM6000, DL9000/DLM9000 and SB5000 series.

            Current Probe 50 MHz/30 ARMS 701929

            Current Probe 50 MHz/30 ARMS 701929

            Current probe front-end powered, recognized automatically and adjust zero position from the operation of the DLM2000, DLM4000, DL6000/DLM6000, DL9000/DLM9000 and SB5000 series.

            Current Probe 10 MHz/150 ARMS 701930

            Current Probe 10 MHz/150 ARMS 701930

            Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

            Current Probe 2 MHz/500 ARMS 701931

            Current Probe 2 MHz/500 ARMS 701931

            Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

            Deskew correction signal source 701936

            Deskew correction signal source 701936

            Improve switching-loss measurements by eliminating skew.  The 701936 Deskew Correction Signal Source accommodates both clamp-on current probes and through-type ‘CT' Current Transformers.

            100:1 Probe 701944

            100:1 Probe 701944

            Passive Probe, 1000Vrms, 400MHz, 100:1, 50MΩ, 1.2m, 'Mini'
            For DL1700, DLM2000, DLM4000, DL/DLM6000,DL9000 and SB5000.
            See also 701945 for 250 MHz version of this same probe.

            100:1 Probe 701945

            100:1 Probe 701945

            Passive Probe, 1000Vrms, 250MHz, 100:1, 50MΩ, 3.0m, 'Mini' with extra-long 3m lead.  Compatible with DL1700, DLM2000, DLM4000, DL/DLM6000, DL9000 and SB5000. See also 701944 for 400 MHz version of this same probe.

            Miniature Passive Probe 701946

            Miniature Passive Probe 701946

            Passive Probe, 400Vrms, 500MHz, 10:1, 10MΩ, 1.3m, 'Miniature Passive Probe' w/ accy kit.
            Optional probe for DLM2000/DLM4000/DL6000/DLM6000/DL9000/SB5000 series.

            Can also be ordered as a substitute for the standard probe when ordering DLM2000/DL6000/DLM6000.

            Soft carrying case for DLM4000 701968

            Soft carrying case for DLM4000 701968

            Three pockets are provided for storing accessories and the user’s manual.

            Rack mount kit for DLM4000 - 701969

            Rack mount kit for DLM4000 - 701969

            Rack mount kit for DLM4000 series.
            EIA/JIS sandard compliant.

            PBL100 Logic Probe 701988

            PBL100 Logic Probe 701988

            701988 (PBL100) Logic Probe

            PBL250 Logic Probe 701989

            PBL250 Logic Probe 701989

            100 kΩ input resistance, toggle frequency of 250 MHz

            B9988AE Printer paper

            B9988AE Printer paper

            Quality paper for the DLM2000/DLM4000/DL850/DL6000/DL9000 and DL750

Location

Ask about this product