DISPLAY: - 3¾ digits LCD with maximum reading 4000. - Overload indication. - Low battery indication. FUNCTIONS: - Peak Hold. - Leakage Current Test. - Test ranges: ACV (600V), ACA (100A) , Ohm, Continuity. - Continuity test below 100Ohm will have buzzer sound. - Alternative for supply frequency. - With LPF (Low Pass Filter) function, 50/60Hz and wide frequency function (40~1KHz).- Maximum conductor size : 30mm.- Dimension : 250mm x 85mm x 35mm.
CAT III 600V 3-1/2 digit LCD with Analog Bargraph. Display Counts: 2000. Auto Ranging. Data Hold and Range Hold Auto Zero. Test Ranges: ACV, ACA, DCV, Resistance, Diode, Continuity. Maximum conductor size 30mm. Continuity test below 25 ohms, buzzer will sound. Auto Power off. Double injection outer case.
CAT III 600V 3-1/2 digit LCD with Analog Bargraph. Display Counts: 2000. Auto Ranging. Data Hold and Range Hold Auto Zero. Test Ranges: ACV, DCA, ACA, DCV, Resistance, Diode, Continuity. Maximum conductor size 30mm. Continuity test below 25 ohms, buzzer will sound. Auto Power off. Double injection outer case.
CAT IV 600V, CAT III 1000V LCD backlit display, with maximum reading of 6600. AC voltage range: 0 to 750V. AC current range: 0 to 660A. DC voltage range: 0 to 1000V. DC Current: 0 to 660A. Resistance measurement to 66 megohms. Data Hold, Min/Max, Autoranging, DCA Zero. Test Ranges: ACV, ACA, Resistance, Frequency, Diode, Continuity. Work light. Auto Power Off. Double Injection outer case.
CAT III 600V 3-3/4 digit LCD Backlit Display, with Analog Bargraph. Display Counts: 4000. Auto Ranging. AC/DC current: 0.1µA to 4000µA. (using test leads). AC current: 0.01A to 400A (using jaw measurement). Ranges: ACV, ACA, DCV, DCA, Resistance, Continuity, Capacitance, and Temperature. Maximum conductor size 30mm. Continuity test below 40 ohms, buzzer will sound. Auto Power off. Double injection outer case.
CAT III 600V Maximum conductor size 30mm. Display counts: 4000. Measures: ACV, DCV, ACA. Measures Phase Sequence. Voltage/Current Harmonics to 25th with THD. W3ø, HV, HA, Phase SEQ, Audible continuity tests. Frequency to 400Hz. Active, Reactive, Apparent power/ energy on. Power Factor, cosø on Single/Three phase systems. Phase sequence.
● Pocket size. ● 4000 counts. ● Full automatic measurement. Voltage measurement. Current measurement. Resistor measurement. ● Data hold function. ● Continuity check. ● Diode measurement. ● Select function. ● Low battery indication. ● Auto off function. ● Flashlight (Auto off in 1 minute).

THE WORLD'S FIRST REAL PRECISION CLAMP METER AC/DC 0.1MA CLAMP METER BEST-SELLING PRODUCT WORLDWIDE NOW!